Validation of a novel instrumented hoof boot with pressure sensors using force plate gait kinetics in horses at walk and trot.

Created on 01 Oct 2026

Authors

Jasmin Keller, Max J Hassenstein, Klaus Jung, Florian Geburek

Published in

Equine veterinary journal. Sep 30, 2026. Epub Sep 30, 2026.

Abstract

Force plates (FP) are considered the gold standard for quantitative equine gait evaluation but are limited to experimental use. An instrumented hoof boot (IHB) with pressure sensors and an inertial measurement unit would allow clinicians to objectively assess kinetic parameters and gait symmetry.
To validate the IHB by comparing kinetic parameters with obtained FP data.
In vivo experiments.
Twenty-seven horses were measured with IHBs on FPs at walk and trot. Mean value kinetic parameters recorded were: (1) peak vertical force (PVF) [N/kg]/peak vertical pressure (PVP) [N/kg]; (2) vertical impulse (AUC) [Nms/kg]; (3) peak loading rate (PLR) [N/ms]; (4) stance duration (StD) [ms] and (5) time of peak vertical force (TPVF) [%stance]/time of peak vertical pressure (TPVP) [%stance]. Agreement and correlation were assessed using Bland-Altman analysis and Kendall's correlation coefficient τ. Significance level was set at α = 5%.
Bland-Altman plots showed an overall moderate to good agreement with following mean difference (bias) and 95% limits of agreement (95%LoA) for IHB and FP: PVF/PVP [N/kg] walk: bias -0.197 (95%LoA: -0.786 to 0.392), trot: bias 0.0516 (95%LoA: -1.01 to 1.11), AUC [Nms/kg] walk: bias -80 (95%LoA: -420 to 260), trot: bias -44.4 (95%LoA: -291 to 202), PLR [N/ms] walk: bias 0.467 (95%LoA: -0.582 to 1.52), trot: bias 6.24 (95%LoA: -0.675 to 13.2), StD [ms] walk: bias 60.4 (95%LoA: -6.36 to 127), trot: bias 28.7 (95%LoA: -1.47 to 58.8), TPVF/TPVP [%stance] walk: bias -1.72 (95%LoA: -8.28 to 4.83), trot: bias -2.8 (95%LoA: -6.43 to 0.832). Correlations were very strong to fair positive.
Small, mixed-breed population, pending repeatability study, ex vivo calibration on manufacturers' behalf.
The IHB is a portable, quick method for kinetic gait analysis that approximates the gold standard FP, offering a promising tool for future clinical use.

PMID:
42817594
Bibliographic data and abstract were imported from PubMed on 01 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 19
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement