Multi-Tier Validation of a Single-Lead Wearable ECG Signal-Processing Pipeline: Clinical Comparison and Algorithmic Benchmarking on Public Expert-Annotated Databases.

Created on 01 Oct 2026

Authors

Josip Vrdoljak, Dora Aletta Racz

Published in

Sensors (Basel, Switzerland). Volume 26. Issue 18. Sep 17, 2026. Epub Sep 17, 2026.

Abstract

Wearable single-lead electrocardiogram (ECG) devices are increasingly used for out-of-clinic rhythm monitoring, but the rigour with which their signal-processing pipelines are validated varies widely across the literature, with most published reports relying on either a single clinical comparison or a single algorithmic benchmark. We propose and apply a multi-tier validation methodology-combining clinical reference comparison, expert-annotated database benchmarking, and a deliberate morphological stress-test-and demonstrate it on the SmartGuard single-lead wearable ECG device and its signal-processing pipeline. The three tiers comprise (i) a within-subject clinical comparison in 31 healthy adult volunteers against a Bionet Cardio 7 limb-lead Lead I reference with cardiologist-confirmed measurements (a two-electrode limb configuration approximating Lead I, not a full diagnostic 12-lead ECG), (ii) algorithmic benchmarking on the Lobachevsky University ECG Database (LUDB, 200 records, expert annotations), and (iii) a robustness stress-test on the QT Database (QTDB, 103 records, hybrid expert annotations). The pipeline integrates discrete wavelet transform-based PQRST delineation with a derivative-based QRS-width refinement, a tangent-method T-wave end estimator, and median-absolute-deviation robust averaging. In the clinical tier, mean within-subject biases were negligible for heart rate, QT, QTc and RR (all p > 0.6) and borderline for QRS duration (+7.3 ms, p = 0.066), with a systematic R-wave amplitude underestimation (-0.15 mV, p < 0.0001). On LUDB, heart-rate and RR-interval agreement were excellent (Pearson r > 0.95) and QRS duration good (r = 0.73, MAE 13.8 ms). On QTDB, performance degraded in line with the increased morphological heterogeneity of the dataset, particularly for QT-related metrics. Despite this minimal mean bias at the population level, individual-record QT and QTc errors showed high dispersion, precluding accurate clinical QT interpretation from single wearable traces in individual patients. Moreover, the resting, healthy-adult design of the clinical tier means its findings cannot be extrapolated to arrhythmic conditions or exercising states. The protocol is described in sufficient detail to serve as a template for evaluating other wearable single-lead ECG devices.

PMID:
42817485
Bibliographic data and abstract were imported from PubMed on 01 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 8
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement