Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

MCA-Mamba-2: A Multi-Channel Attention State-Space Network for Ultrasonic Guided Wave Damage Detection in Small-Diameter Pipes.

Created on 01 Oct 2026

Authors

Qiuyu Yu, Ruohua Zhou, Zhengxian Liang, Yajun Liu

Published in

Sensors (Basel, Switzerland). Volume 26. Issue 18. Sep 15, 2026. Epub Sep 15, 2026.

Abstract

Ultrasonic guided wave (UGW) inspection of small-diameter pipes is complicated by the narrow usable frequency band and by strong susceptibility to measurement noise, both of which degrade the reliability of damage identification. This study proposes a multi-channel attention Mamba-2 (MCA-Mamba-2) network that couples a convolutional front end with a bidirectional Mamba-2 state-space backbone and combines multi-head self-attention with channel attention for feature fusion. The network takes as input the four waveforms recorded simultaneously by a circumferential receiver array so that the input tensor has four physical channels that are subsequently expanded into learned feature channels. A dataset of ten damage states, spanning non-through-wall abrasions, through-wall holes and one multi-defect case, was acquired on a 20 mm outer-diameter steel pipe specimen. Averaged over three independent runs, MCA-Mamba-2 reaches 98.01 ± 0.85% accuracy on noise-free signals and 81.09 ± 1.74%, 83.65 ± 1.34%, 82.49 ± 0.20% and 84.15 ± 1.04% on 0 dB test sets contaminated with white, pink, Gaussian and Laplacian noise respectively, exceeding the Mamba-2 baseline in all sixteen tested noise-type and SNR combinations, by up to 17.87 percentage points. An ablation study attributes the improvement principally to the convolutional mixing block. A cross-noise evaluation reveals that accuracy drops by 59.80 percentage points, on average, at 0 dB when the training and testing noise distributions differ, indicating that the matched-noise accuracies are not indicative of robustness to unknown noise conditions; however, a single model trained on a mixture of all noise types and SNR levels recovers an average accuracy of 91.21% across the sixteen test conditions. Because each damage state was recorded in a single acquisition session, the dataset was partitioned at the level of individual records rather than by session, and the reported accuracies should be interpreted as an upper bound on the performance attainable on independently acquired data. The results were obtained on a single pipe geometry with fixed defect positions and synthetically added noise; extension to other geometries and to field measurements remains to be demonstrated.

PMID:
42817431
Bibliographic data and abstract were imported from PubMed on 01 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 15
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement