Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Unfolding new horizons: Machine learning applications for pediatric intussusception - A systematic review and meta-analysis.

Created on 04 Oct 2026

Authors

Letícia Rocha Campos, Solonas Symeou, Gisella Chiara Carpi, Dan Poenaru

Published in

Journal of pediatric surgery. Pages 163518. Oct 03, 2026. Epub Oct 03, 2026.

Abstract

Pediatric intussusception is among the most common surgical emergencies in early childhood. Ultrasonography is the diagnostic standard but remains operator-dependent, and no validated machine learning (ML) tools exist for triage or prognostic stratification. We systematically evaluated ML models for diagnosis and prognosis of pediatric intussusception.
This PROSPERO-registered systematic review and meta-analysis (CRD420251073590) included studies evaluating ML models for pediatric intussusception diagnosis or prognosis reporting sensitivity, specificity, or AUC. Risk of bias was assessed with PROBAST. A bivariate random-effects model was applied to internally and externally validated datasets, with subgroup analyses by input modality.
Eleven studies (37 model variants; 36,863 patients) were included. Internally validated ultrasound (US) models (k=4) achieved pooled sensitivity 0.914 (0.829-0.959) and specificity 0.980 (0.939-0.994). Externally validated US models (k=3) showed sensitivity 0.946 (0.909-0.969) and specificity 0.958 (0.918-0.979). Abdominal radiograph (AXR) triage models performed lower externally (sensitivity 0.800 [0.725-0.859]; specificity 0.748 [0.662-0.819]), consistent with a screening role. Notably, AI assistance improved junior readers' specificity by 15.9 percentage points overall (up to 37.6 points for the most junior readers), and AI-assisted junior sonographers cut ultrasound examination time by 61% without loss of diagnostic accuracy. Possible publication bias was detected (Deeks' p=0.021). Prognostic AUCs ranged from 0.555 to 0.962.
US-based ML models demonstrate high, externally robust diagnostic accuracy. AXR models suit screening but need further validation. No study reported clinical endpoint data. Multicenter prospective validation outside Asia and regulatory pathway development are required before implementation. Until then, AXR-based models should be positioned as an adjunct that raises suspicion, never as a gate that determines which child receives an ultrasound.
Level III - Systematic Review and Meta-Analysis of retrospective diagnostic accuracy studies.

PMID:
42829175
Bibliographic data and abstract were imported from PubMed on 04 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 2
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement