Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Mechanical Characterization of Fibrin-Based Blood Clot Analogues for Modeling Intracerebral Hemorrhage.

Created on 04 Oct 2026

Authors

Prabhat Kumar, Adrian Liu, Yigit Can Senol, Daniel Leong, Nanditha Krishnan, Luis E Savastano

Published in

Annals of biomedical engineering. Oct 03, 2026. Epub Oct 03, 2026.

Abstract

Intracerebral hemorrhage (ICH) carries high mortality and long-term disability. Development of minimally invasive surgical (MIS) evacuation devices is limited by the lack of reproducible clot analogues that reproduce key mechanical features of human ICH clots. This study evaluates the structural and mechanical behavior of engineered clot analogues benchmarked against patient-derived ICH clots.
Clot analogues were formulated at FFP:pRBC ratios of 85:15, 90:10, and 95:5. Microstructure was qualitatively assessed using scanning electron microscopy (SEM), and mechanical behavior was characterized by strain sweep rheology, flow sweep viscosity, and axial compression. Mechanical properties were benchmarked against three patient-derived ICH specimens.
SEM revealed a transition from cell-dominated (85/15) to fibrin-dominant (95/5) microstructures, with 90/10 exhibiting an intermediate architecture. All analogues demonstrated predominantly solid-like behavior (G' > G″), with storage modulus increasing from 334.3 ± 55.0 Pa (85/15) to 499.9 ± 140.5 Pa (95/5) (p = 0.037). Tanδ values overlapped with patient-derived specimens, suggesting similar viscoelastic regimes despite differences in absolute stiffness. Peak viscosity was significantly greater for 85/15 than for 90/10 and 95/5 (p < 0.001). Compressive stress increased numerically with FFP content but did not differ significantly among formulations (p = 0.053).
Fibrin-based clot analogues provide a reproducible and tunable platform for modeling selected mechanical characteristics of ICH clots. The formulations span distinct mechanical behaviors that may support standardized benchtop and cadaveric evaluation of MIS ICH evacuation technologies.

PMID:
42829390
Bibliographic data and abstract were imported from PubMed on 04 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 12
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement