Establishment and Application of a Quantitative Lipemia Index as a Novel Indicator for Assessing Lipemic Interference in Clinical Chemistry.

Created on 06 Oct 2026

Authors

Haifeng Xie, Shuhua Bao, Pengcheng Tong, Peng Li, Zhe Shen, Jinlong Wei

Published in

Journal of clinical laboratory analysis. Pages e70378. Oct 06, 2026. Epub Oct 06, 2026.

Abstract

Lipemia is a common pre-analytical interference in clinical chemistry. Triglyceride (TG) concentration is commonly used as a surrogate indicator for lipemic interference, but its predictive reliability is limited by heterogeneity in lipoprotein particle composition. This study aimed to establish and validate a quantitative Lipemia index (LI) assay for direct measurement of serum turbidity, compare its predictive value with TG, and evaluate its clinical applicability through reference interval estimation and correlation with interference deviations in native patient samples.
The LI assay was developed on a Beckman Coulter AU5800 analyzer by measuring ΔA (A660-A800 nm). Performance was validated per CLSI guidelines: precision (EP05-A3), detection capability (EP17-A2), linearity (EP06-ED2), method comparison (Passing-Bablok regression, Bland-Altman analysis), reference interval (EP28-A3c), and dilution recovery (EP07-A2). LI's predictive value for lipemic interference was compared to TG using deviations in total protein assays (single- vs. double-reagent methods).
The LI assay demonstrated precision with CV ≤ 2.23% and linearity (0.05-30.87 mmol/L TG-equivalent). It correlated strongly with the reference TG method (ρ = 0.998, p < 0.0001). In predicting assay interference, LI showed a closer correlation with total protein deviations than did TG (rs = 0.822 vs. 0.770). A reference interval of 0.093-0.240 was established for healthy adults. Dilution recovery (90%-110%) confirmed accuracy.
The quantitative LI assay provides a standardized, clinically validated measure of lipemic interference aligning more directly with the optical nature of clinical chemistry testing than TG measurement. These findings support its analytical validity, utility as a predictor of turbidity interference, and clinical applicability.

PMID:
42834850
Bibliographic data and abstract were imported from PubMed on 06 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 22
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement