Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Prospective multicenter study on patient-related outcomes of orbital floor reconstruction using ultrahigh-molecular-weight polyethylene.

Created on 09 Oct 2026

Authors

Stefanie Wilhelm, Raimund Preidl, Konstantinos Afxentiou, Marco Kesting, Adem Aksu, Rainer Lutz, Lucas Ritschl, Katharina Pippich, Achim von Bomhard

Published in

PloS one. Volume 21. Issue 10. Pages e0359326. Epub Oct 08, 2026.

Abstract

This prospective, multicenter clinical study evaluated patient-reported outcomes, functional recovery, and quality of life following orbital floor reconstruction using ultra-high-molecular-weight-polyethylene (UHMWPE) implants. The study emphasized both subjective recovery and the clinical performance of the implant material. Between June 2022 and July 2023, 46 adult patients (≥ 18 years of age) with radiologically confirmed orbital floor fractures requiring surgical reconstruction were enrolled and completed the full follow-up protocol. Surgical reconstruction was performed according to standardized procedures using UHMWPE implants. Pre- and postoperative CT or CBCT imaging was obtained when clinically indicated; radiological outcomes of this cohort have been reported separately. Pre- and postoperative evaluations included an assessment of pain, swelling, ocular motility, diplopia, sensory function, foreign body sensation, overall satisfaction and orbital volume, which was measured using three-dimensional imaging. Intraoperative parameters were also recorded. Patient-reported outcomes were collected through validated questionnaires and visual analogue scales, repeated at each visit, follow-up examinations were performed approximately one day, ten weeks, six months, and twelve months after surgery. Overall, clinical and patient-reported outcomes improved over the follow-up period. Pain intensity declined markedly within the first week after surgery and remained consistently low thereafter. Swelling, numbness, and the sensation of a foreign body gradually subsided, with almost complete resolution after one year. Furthermore, imaging confirmed stable anatomical reconstruction without implant displacement or volume loss. In general patient satisfaction increased steadily throughout the observation period, reaching near-maximal levels after twelve months. No cases of infection, inflammatory reaction or implant-related complication were recorded. In this prospective cohort, orbital floor reconstruction using UHMWPE was associated with favorable functional, aesthetic and patient-reported recovery over 12 months. These findings support the value of incorporating patient-centered outcomes into the assessment of recovery after orbital trauma, while comparative effectiveness and long-term safety require further controlled studies.

PMID:
42848811
Bibliographic data and abstract were imported from PubMed on 09 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 4
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement