Reliability of Implant- vs. Bone-Based Postoperative Measurements After Anatomic Total Shoulder Arthroplasty Using CT Imaging.

Created on 10 Oct 2026

Authors

Nazanin Daneshvarhashjin, Philippe Debeer, Filip Verhaegen, Lennart Scheys

Published in

Journal of orthopaedic research : official publication of the Orthopaedic Research Society. Volume 44. Issue 10. Pages e70292.

Abstract

In anatomic total shoulder arthroplasty (aTSA) research, postoperative anatomical measurements are often referenced to the reamed glenoid bone surface because the glenoid component is not fully visible on CT. However, the reliability of measurements based directly on the implant (implant-based method) and their agreement with the commonly used bone-based method remain unclear. In this study, CT scans from 29 patients undergoing primary aTSA were used to calculate postoperative glenoid positioning (translations, version, inclination) and HHS in the anterior-posterior (HHSAP) and superior-inferior (HHSSI) directions using both methods. The bone-based method referenced measurements to 3D postoperative scapular bone reconstructions, whereas the implant-based method used CT-registered digital glenoid component models. Inter- and intra-rater reliability of implant-based measurements were assessed using intraclass correlation coefficients (ICCs), and agreement between methods was evaluated using ICCs and Bland-Altman analyses. The implant-based approach demonstrated high inter- and intra-rater reliability (ICCs > 0.88), with minimal detectable changes below commonly cited clinical thresholds. The agreement between implant- and bone-based methods was moderate-to-excellent overall (ICC > 0.52), although significant bias and/or wide limits of agreement were observed for version, inclination, superior-inferior implant positioning, and HHSSI. Compared to implant-based measures, bone-based estimates showed a bias toward more superior implant positioning and superior HHSSI, greater retroversion, and more medialized implant positioning. In conclusion, direct implant-to-CT registration is a reliable method for 3D postoperative measurements after aTSA. Implant- and bone-based measurements can be used interchangeably for anterior-posterior implant positioning and HHSAP, but not for other measures when high precision is required. LEVEL OF EVIDENCE: Basic science study.

PMID:
42856085
Bibliographic data and abstract were imported from PubMed on 10 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement