Abstract

BackgroundTraditional mirror therapy relies on fixed kinematic symmetry, often neglecting the trade-offs between movement accuracy, stability, and muscular effort. This study developed a Multimodal Adaptive Mirror Therapy system featuring a multi-objective controller for personalized gait rehabilitation.ObjectiveTo develop and evaluate a multimodal adaptive mirror therapy system that integrates gait kinematics, postural stability, and muscular activation into a unified multi-objective optimization framework for personalized gait rehabilitation.MethodsTwenty-six subjects underwent asymmetric gait training with unilateral limb restraint to simulate asymmetric gait patterns. The proposed system integrated camera-based gait data, inertial measurement unit (IMU)-based stability metrics, and electromyography (EMG) activation into a unified objective function. Optimization was dynamically adjusted via a weighted harmonic mean of multimodal scores. Normalized mutual information (NMI) was used to quantify dependencies, while interquartile range (IQR) analysis evaluated controller stability.ResultsNMI analysis revealed significant dependencies between all modalities (p < 0.05), with the training parameter showing the strongest correlation with stability (NMI = 0.342). The multimodal controller achieved balanced, near-optimal performance, yielding median scores of 97.81% for stability and 92.44% for gait. Notably, it exhibited the lowest inter-participant variability among all strategies in the stability domain (IQR: 24.80%), compared to substantially wider dispersions observed under unimodal controllers.ConclusionThis study demonstrated that a multimodal, closed-loop control scheme can effectively resolve performance trade-offs in gait training. By transitioning from rigid imitation to dynamic multi-objective optimization, the system provided a robust, intelligent closed-loop platform, establishing a practical foundation for patient-centered robotic rehabilitation.

PMID:
42856019
Bibliographic data and abstract were imported from PubMed on 10 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 4
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement