Benchmarking Drug Library Compliance and Alert Rates in Smart Infusion Pumps: A Multicenter Retrospective Study.

Created on 12 Oct 2026

Authors

Ivens Souza, Mona Mourad, Samantha J Burton, Jaculin Cole, Caio Plopper, Sofia R Fernandez, Aftab Alam

Published in

Cureus. Volume 18. Issue 9. Pages e116103. Epub Sep 11, 2026.

Abstract

 Smart infusion pumps with dose error-reduction software (DERS) generate alerts to prevent infusion programming errors. However, high alert volumes may contribute to alert fatigue and impact workflow efficiency. Benchmarking continuous quality improvement (CQI) data across institutions may help identify opportunities to optimize drug library (DL) performance. This study evaluated the relationship between DL compliance and alert-related metrics using a benchmarking approach.
 A retrospective multicenter analysis of smart infusion pump data was conducted across 90 institutions (99 data pulls), including 13,749,759 infusions. Key metrics included DL compliance, alert rate, override rate, and alerts resulting in reprogramming ("good catches"). Facilities with DL compliance <95% and ≥95% were compared, and Spearman correlation analyses were performed to assess associations between DL compliance and alert-related outcomes.
 The overall DL compliance rate was 95.9%. The mean alert rate was 33.3% (±12.20), and the overall override rate was 96.4%. On average, one good catch occurred for every 34.5 DERS infusions. Benchmarking across institutions showed no statistically significant differences in alert rates, override rates, or good catch rates between facilities with DL compliance ≥95% and those with <95%. Correlation analyses demonstrated only weak associations between DL compliance and alert rate, override rate, and good catch metrics.
 Benchmarking CQI data across institutions demonstrates that high DL compliance alone does not necessarily indicate optimized smart infusion pump performance. Incorporating alert and override metrics into CQI analyses may help reduce non-actionable alert burden and support safer, more efficient infusion workflows.

PMID:
42861187
Bibliographic data and abstract were imported from PubMed on 12 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement