Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

ZnO-Pd nanobolts-based immunoanalytical detection of a pancreatic cancer biomarker and its software-assisted digital quantification.

Created on 12 Oct 2026

Authors

Akanksha Deshwal, Rajesh, Sang J Chung, Prashant Mishra, Ravi Mani Tripathi

Published in

Nanoscale horizons. Oct 12, 2026. Epub Oct 12, 2026.

Abstract

Early and reliable detection of pancreatic cancer (PC) remains a formidable clinical challenge, largely owing to the limited sensitivity, operational unreliability, and enzyme dependence of existing carbohydrate antigen 19-9 (CA19-9) immunoassays. In this work, we determine for the first time that ZnO-Pd nanobolts show intrinsic oxidase-like activity. Furthermore, this attribute was used to fabricate a colorimetric immunoanalytical sensor based on nanozymes for the sensitive and specific detection of CA19-9, a biomarker for PC. In this research, immunoreagent optimization, smartphone-assisted signal analysis, and kinetic analysis of nanozyme catalytic activity were employed to enable highly sensitive detection of CA19-9. Enzyme-kinetic studies showed low Michaelis-Menten constants (KM) of 0.99 mM, as well as high turnover numbers (kcat) and catalytic efficiencies (kcat/KM) of 4.48 × 10-4 s-1 and 0.453 M-1 s-1, respectively, indicating high substrate affinity. The optimized nanozyme was functionalized with Goat anti-mouse IgG (GAM IgG), thereby facilitating antigen recognition and signal transduction. The proposed immunoassay demonstrated high analytical sensitivity (LOD of 0.000159 U mL-1 and LOQ of 0.000482 U mL-1) and exceptional selectivity even in complex biological matrices. Software-assisted signal processing enabled precise assessment of the limit of detection (LOD) of 0.000359 U mL-1 and the limit of quantification (LOQ) of 0.00108 U mL-1. The practical utility of the fabricated immunoassay was further examined using human serum, with recovery rates ranging from 100.6% to 102%, indicating high accuracy and reproducibility. Furthermore, the successful digitalization of assay results into software-based readable data demonstrates the sensing approach's potential for portable, cost-effective, and point-of-care PC diagnostics.

PMID:
42861634
Bibliographic data and abstract were imported from PubMed on 12 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 4
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement