Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Open-Irrigated Versus Non-Irrigated Catheters in SVT Ablation: Substrate-Specific Outcomes in AVRT and AVNRT.

Created on 15 Oct 2026

Authors

Marcos Javier Duarte-Sau, José Cruz Arzola-Hernández, Nancy Elena Guzmán-Delgado, Luis Gerardo González-Barrera

Published in

Pacing and clinical electrophysiology : PACE. Oct 14, 2026. Epub Oct 14, 2026.

Abstract

Open-irrigated catheters (OIC) provide improved cooling, deeper lesion formation, and enhanced safety during radiofrequency catheter ablation (RFCA). However, comparative evidence regarding substrate-specific outcomes with OIC versus non-irrigated catheters (NIC) for supraventricular tachycardia (SVT) remains limited. This study compared acute ablation success (AAS) and recurrence after first-time RFCA using OIC versus NIC, with particular emphasis on differential outcomes in atrioventricular re-entrant tachycardia (AVRT) and atrioventricular re-entrant tachycardia (AVNRT).
A retrospective cohort of consecutive patients undergoing first-time RFCA for AVNRT or AVRT between 2017 and 2023 was analyzed. Patients were categorized by catheter type (OIC vs. NIC). Primary outcomes were AAS and SVT recurrence during 24-month follow-up. Multivariate logistic regression and Cox proportional hazards models were used for adjusted analyses. Subgroup analyses were performed for AVNRT and AVRT.
Among 302 procedures, OIC were used in 113 (37.4%). Overall AAS was achieved in 85.4% of cases (92.0% OIC vs. 81.5% NIC; p = 0.012). Recurrence occurred in 17.9% (7.1% OIC vs. 24.3% NIC; p < 0.001). In multivariable analyses, OIC use was independently associated with higher AAS (adjusted RR 1.12; 95% CI 1.05-1.20; p = 0.001) and lower recurrence (adjusted HR 0.24; 95% CI 0.12-0.52; p < 0.001). In the AVRT subgroup, OIC use was associated with higher AAS (89.9% vs. 76.6%; p = 0.014) and lower recurrence (adjusted HR 0.25; 95% CI 0.11-0.57; p < 0.001), whereas no significant differences were observed in AVNRT.
In this cohort, OIC use was associated with higher AAS and lower recurrence, with the favorable association primarily observed in AVRT rather than AVNRT. These findings support further evaluation of substrate-specific catheter selection, particularly for accessory pathway ablation.

PMID:
42876197
Bibliographic data and abstract were imported from PubMed on 15 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 14
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement