Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Nutrient Calculation Accuracy, Expert-Rated Clinical Appropriateness and Safety Indicators, and Reproducibility of Large Language Model-Generated Diet Plans for Polyendocrine Metabolic Ovarian Syndrome: A Real-Case-Based Evaluation.

Created on 16 Oct 2026

Authors

Ayşenur Çalık, Pınar Ece Demiray, Ayşe Betül Bilen, Gülen Ecem Kalkan, Muazzez Garipağaoğlu

Published in

Nutrients. Volume 18. Issue 19. Sep 28, 2026. Epub Sep 28, 2026.

Abstract

Background/Objectives: This study evaluated the nutrient calculation accuracy, reproducibility, and expert-rated clinical appropriateness and safety indicators of three-day diet plans generated for women with polycystic ovary syndrome (PCOS), recently proposed to be termed polyendocrine metabolic ovarian syndrome (PMOS). Methods: Anonymized data from six women with heterogeneous PMOS profiles, purposively selected from a single clinic, were converted into standardized Turkish prompts and submitted to ChatGPT-4, Claude Sonnet 4.6, Gemini 2.5 Flash, and Mistral 2.0 through free web interfaces. Three independent generations per case-model combination yielded 216 daily menus. LLM-reported nutrient values were compared with BeBiS 9.0 calculations. Reproducibility was assessed using intraclass correlation coefficients (ICCs). Two experts independently evaluated the first generated plan for each case-model combination using a study-specific clinical appropriateness rubric and red-flag checklist. Results: No model achieved consistently low error across nutrients. Claude Sonnet 4.6 showed the lowest percentage errors for energy, carbohydrate, and fiber; ChatGPT-4 for protein; and Mistral 2.0 for fat. Gemini 2.5 Flash showed the largest percentage errors across all nutrients and a mean energy bias of +531.1 kcal. ChatGPT-4 showed comparatively higher plan-level reproducibility, while the remaining models generally showed poor reproducibility. Claude Sonnet 4.6 had the highest descriptive clinical appropriateness scores and Gemini 2.5 Flash the lowest, but no pairwise differences remained significant after Holm correction. Gemini 2.5 Flash generated the most confirmed study-specific red flags (n = 28), with all six cases meeting the criterion for the "masked low-energy" indicator. Conclusions: LLM-generated diet plans showed model-dependent calculation errors and limited reproducibility, and the present findings do not support their independent or unsupervised use as individualized clinical nutrition recommendations.

PMID:
42884656
Bibliographic data and abstract were imported from PubMed on 16 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 21
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement