Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

ZnO/ZIF-8@Au nanoarchitectures with nanoconfinement-enhanced plasmonic coupling for ultrasensitive photoelectrochemical detection of malondialdehyde.

Created on 17 Oct 2026

Authors

Xiaoxia Han, Dan Li, Yiran Li, Lizhen Huang, Bin Dong, Sui-Dong Wang, Hao Wu

Published in

Analytica chimica acta. Volume 1424. Pages 346222. Nov 22, 2026. Epub Sep 05, 2026.

Abstract

Malondialdehyde (MDA) is a pivotal oxidative stress biomarker implicated in cardiovascular diseases, neurodegeneration, and cancer; however, its trace quantification in complex biological matrices remains analytically daunting. Photoelectrochemical (PEC) sensing offers inherently low background noise and exceptional sensitivity for trace bioanalysis. Nevertheless, efficiently translating molecular recognition into amplified PEC signals remains a challenge.
We report a nanoconfinement-mediated PEC interface that integrates covalent molecular conjugation with plasmonic amplification within a crystalline matrix scaffold. Within this nanoconfined environment, localized Au nanoparticles serve as plasmonic amplifiers that anchor 4-aminothiophenol (4-ATP) receptors. Upon MDA recognition, the optimized sensor exhibits dual linear detection ranges spanning 0.001 to 1.0 nmol L-1 (R12 = 0.9928) and 1.0 to 1000 nmol L-1 (R22 = 0.9992), yielding an ultralow detection limit of 0.3 pmol L-1.
The confined Schiff-base reaction between 4-ATP and MDA generates an interfacial reaction product, leading to a new absorption band at approximately 450 nm and modulation of the Au LSPR band. This change is mainly attributed to the altered local dielectric environment around Au NPs. Wavelength-dependent operando transient photovoltage spectroscopy (TPV) provides mechanistic evidence that plasmon-driven hot-carrier injection augments PEC signal output. Overall, this work establishes an interface-engineering paradigm that integrates molecular conjugation with plasmonic coupling, offering a promising blueprint for the PEC detection of small-molecule biomarkers.

PMID:
42887970
Bibliographic data and abstract were imported from PubMed on 17 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 8
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement