Assessment of Calculation Grid Size Impact on Plan Quality and Gamma Evaluation Metrics in Intracranial Stereotactic Radiotherapy.

Created on 18 Oct 2026

Authors

Ravindra Shende, Joyce Alexis, R S Rahul

Published in

Journal of medical physics. Volume 51. Issue 3. Pages 546-556. Epub Sep 23, 2026.

Abstract

This study aimed to evaluate the impact of dose calculation grid size on dosimetric accuracy, plan quality indices, and patient-specific quality-assurance (QA) outcomes in intracranial stereotactic radiotherapy (SRT).
Fifteen retrospective intracranial SRT plans treated with HyperArc volumetric modulated arc therapy were re-planned using five dose calculation grid sizes of 1.0, 1.25, 1.5, 1.75, and 2.0 mm in the Eclipse treatment planning system. All plans were made to deliver 30 Gy in 5 fractions using 6 MV flattening-filter-free beams and calculated using the Anisotropic analytical algorithm. Plan quality was evaluated using multiple plan quality metrics, including RTOG quality coverage index (QI), Paddick conformity index, homogeneity index, and gradient index (GI). Dose spillage outside the target was assessed using volumetric dose indices. Patient-specific QA was performed using SRS MapCHECK with gamma-analysis under multiple criteria. Statistical comparisons were conducted using dependent paired t-tests, repeated-measure analysis of variance, and Pearson correlation coefficient analysis.
Increasing the dose calculation grid size resulted in a systematic increase in planning target volume mean dose and a corresponding reduction in D95%, indicating loss of target coverage attributable to spatial dose averaging. GI showed the strongest dependence on grid size, demonstrating progressive degradation of dose fall-off with coarser grids. Low-dose spillage to the normal brain and brainstem increased significantly with increasing grid size, while distant organs at risk were comparatively less affected. Gamma passing rates declined progressively with increasing grid size, particularly under the most stringent evaluation criteria.
Study highlights that dose grid size variations significantly influence dosimetric accuracy, plan quality, and QA robustness in intracranial SRT. Coarser calculation grids compromise target coverage and gradient fidelity, while finer grids (≤1.25 mm) preserve near-reference dosimetric accuracy. Adopting a finer calculation grid ensures reliable dose computation, consistent patient-specific QA, and optimal clinical performance in SRT.

PMID:
42891483
Bibliographic data and abstract were imported from PubMed on 18 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement