The Stryker Perform and Univers Apex short stems have different patterns of stress shielding but comparably low rates of loosening after reverse total shoulder arthroplasty.

Created on 18 Oct 2026

Authors

Leonard Stokes, Vidhur Polam, Michelle Gosselin, Andrew Nahr, Kevin Kruse, Patrick J Denard

Published in

Journal of shoulder and elbow arthroplasty. Volume 10. Issue 4. Pages 100091. Epub Sep 15, 2026.

Abstract

The purpose of this study was to compare short-term radiographic outcomes between the Apex Univers Revers (Arthrex, Inc.) and the Stryker Perform Reversed (Stryker Inc.) short-stem reverse total shoulder arthroplasty (rTSA) implants.
A retrospective review was conducted of patients who underwent rTSA between 2021 and 2023 by 2 fellowship-trained surgeons at separate institutions. Consecutive primary cases with ≥2 years of follow-up were included. Immediate and final post-operative radiographs were reviewed for signs of loosening and stress shielding, which were graded in 5 zones and classified according to the Schnetzke bone adaptation grades. Partial or complete calcar osteolysis was also recorded. Multivariable regression was performed, and multiplicity was controlled within outcome families using the Holm method.
A total of 40 Univers Revers and 46 Stryker Perform implants met the study criteria. Groups were similar in age, sex, diagnosis, and follow-up duration. By zone, remodeling was more frequent with Univers Revers in Zone 2 (32.5% vs. 7.5%; adjusted P = .05) and Zone 5 (35.0% vs. 10.0%; adjusted P = .070). All other zones showed no significant differences between groups (all adjusted P > .05). Partial calcar osteolysis was observed in 1 Univers Revers (2.5%) and 1 Stryker Perform (2.2%) (P = 1.000). The proportion of implants at risk for loosening was similar between Univers Revers (2.5%) and Stryker Perform (6.5%) (P = .620). Subsidence occurred in 1 Univers Revers (2.5%) and 2 Stryker Perform (4.3%) (P = 1.000); all stabilized without progression or need for revision. One of the Stryker Perform cases demonstrating subsidence also exhibited a minor stem shift, corresponding to 3 unique implants (6.5%) considered at risk for loosening.
There is no apparent difference in short-term risk for loosening between the Stryker Perform and Arthrex Apex Univers Revers short stem designs in rTSA. Remodeling patterns differed by zone, which may reflect the differing stem designs.

PMID:
42892925
Bibliographic data and abstract were imported from PubMed on 18 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 19
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement