Visualization of the Eustachian Tube Cartilage on Delayed Contrast-enhanced 3D-MR Imaging: A Preliminary Comparison between Ionic and Non-ionic Gadolinium-based Contrast Agents.

Created on 19 Oct 2026

Authors

Shinji Naganawa, Rintaro Ito, Mariko Kawamura, Toshiaki Taoka, Masumi Kobayashi, Tadao Yoshida

Published in

Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. Volume 25. Issue 4.

Abstract

To evaluate whether delayed contrast-enhanced 3D MRI using a non-ionic gadolinium-based contrast agent enables reliable visualization of the Eustachian tube cartilage (ETC) and to compare the signal intensity characteristics between ionic and non-ionic contrast agents.
Thirty-five participants underwent 3T fat-suppressed 3D-Motion-Sensitized Driven-Equilibrium (MSDE) T1-weighted MRI 4 hr after receiving either gadobutrol (non-ionic, n = 18) or gadoterate meglumine (ionic, n = 17). The visualization of the ETC was qualitatively evaluated using a 5-point Likert scale by 2 neuroradiologists. Signal intensity ratios relative to the medulla were measured for the ETC, nasal turbinate mucosa, and lateral pterygoid muscles. Semi-automated 3D segmentation of the ETC was performed in representative cases.
The inter-observer agreement for the qualitative scores was substantial (κ = 0.786-0.808). Qualitative ETC visual scores were significantly higher in the gadobutrol group than in the gadoterate meglumine group (median, 5.0 vs. 4.0; P < 0.001). The ETC-to-medulla signal intensity ratios were significantly higher with gadobutrol bilaterally (right: 1.52 ± 0.20 vs. 1.21 ± 0.19, P < 0.0001; left: 1.54 ± 0.26 vs. 1.24 ± 0.22, P = 0.00088). No significant differences were observed in control soft tissues. Furthermore, semi-automated 3D segmentation of the ETC was successfully achieved in representative cases using high-resolution MR datasets with a non-ionic contrast agent.
Delayed contrast-enhanced 3D-MRI with a non-ionic contrast agent allows clear, high-contrast visualization and 3D reconstruction of the ETC, outperforming the ionic agents.

PMID:
42893880
Bibliographic data and abstract were imported from PubMed on 19 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 3
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement