Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Post-acne Erythema: A Systematic Review of Randomized Controlled Trials on the Comparative Efficacy and Safety of Interventions Across Clinical, Instrumental, and Patient-Reported Outcomes.

Created on 19 Oct 2026

Authors

Ahmed Alhussain, Mohammad Majrashi, Khalid Omar AlMubarak, Rayan Faleh Alqahtani, Nasir Abdullah Al Melhem, Shahad Saad S AlShammari, Thamer M Mubarah, Ghadeer A Alameer, Fatima Mohammed Al-Sawad, Hadeel Hesham Buali, Raghad Khalid Alenezi, Mohammed A Ababtain, Bader Ahmed Sabei, Abdulelah F Alshehri

Published in

Cureus. Volume 18. Issue 9. Pages e116495. Epub Sep 18, 2026.

Abstract

Post-acne erythema (PAE) is a persistent acne sequela without an established standard treatment. This systematic review evaluated the comparative efficacy and safety of interventions tested in randomized trials. PubMed/MEDLINE, Scopus, and Web of Science were searched from inception through August 1, 2026. Randomized parallel-group and split-face trials reporting erythema outcomes were eligible. Risk of bias was assessed with the Cochrane Risk of Bias 2 (RoB 2) tool. Heterogeneity precluded meta-analysis, and available findings were synthesized narratively. Nine trials involving 301 participants contributed 11 pairwise comparisons. Against untreated or blank controls, favorable effects were reported for picosecond alexandrite laser, narrow-spectrum vascular intense pulsed light (IPL), and non-cross-linked hyaluronic acid mesotherapy. A 577-nm semiconductor laser showed interim instrumental benefit, but blinded assessors found no final between-side difference. In active-treatment and add-on comparisons, narrow-spectrum IPL was favored over broad-spectrum IPL, neodymium-doped yttrium aluminum garnet (Nd) laser added to low-dose isotretinoin was favored over isotretinoin alone, and 577-nm pro-yellow laser was favored over topical brimonidine. Botulinum toxin type A was favored over broadband light at the earliest assessment only. Fractional laser and pulsed dye laser did not differ significantly, while delicate pulsed light and Q-switched 1064-nm Nd laser showed no sustained difference at the final assessment. Adverse events were mild and transient, although pigmentation and blistering occurred with one broad-spectrum IPL protocol. Five trials had some concerns, and four had high overall risk of bias. Trials suggested potential benefits, but small samples, heterogeneity, short follow-up, and reporting limitations precluded identification of a preferred treatment. Larger, prospectively registered trials using blinded assessment and standardized outcomes are needed.

PMID:
42894818
Bibliographic data and abstract were imported from PubMed on 19 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 14
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement