Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Dynamic control of carbon-ion radiation dose distribution amid respiratory motion challenges: A review of prediction research using geant4 and deep learning physics-constrained models.

Created on 21 Oct 2026

Authors

Jianhua Ding, Peng Li, Chai Hong Yeong

Published in

Journal of applied clinical medical physics. Volume 27. Issue 11. Pages e70766.

Abstract

Carbon ion radiotherapy (CIRT) offers superior dose conformity and biological effectiveness; however, its precision is highly sensitive to respiratory motion, leading to dose uncertainty and interplay effects that compromise treatment accuracy.
A comprehensive literature synthesis was conducted on studies employing motion-resolved imaging techniques (e.g. SMEIR), dynamic dose prediction, 4D robust planning, and hybrid adaptive methods for CIRT. The study emphasised the use of Geant4 Monte Carlo simulations combined with deep learning models, including physics-informed neural networks, to simulate and predict dose perturbations caused by respiratory motion. This review also examined clinical treatment planning systems, radiobiological modelling, and adaptive strategies to mitigate the effects of motion.
The integration of Geant4 with deep learning enabled high-fidelity, computationally efficient dose prediction under respiratory motion, improving accuracy in dose localization and adaptation. Motion management techniques such as respiratory gating, rescanning, and 4D robust optimization demonstrated enhanced tumor control and normal tissue sparing. Hybrid models combining Monte Carlo data and AI inference show promise for near-real-time adaptive therapy. Despite these advances, challenges remain, including limited motion-rich datasets, computational demands for real-time recalculations, and the complexity of incorporating variable relative biological effectiveness (RBE) into adaptive planning.
Combining Geant4-based Monte Carlo simulations with deep learning frameworks shows emerging promise for controlling carbon ion dose distributions amid respiratory motion, though direct clinical validation for this combination remains limited. These hybrid models may enhance the precision and adaptability of CIRT, offering improved outcomes. Future efforts should focus on clinical validation, standardization, and overcoming computational and data limitations to facilitate clinical translation of motion-adaptive CIRT. These approaches remain at Technology Readiness Levels (TRL 3-5) and require prospective clinical validation before routine implementation.

PMID:
42900519
Bibliographic data and abstract were imported from PubMed on 21 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 19
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement