Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Decoupling Pore Size and Porosity in Sheet-Based TPMS Scaffolds: Assessing Early Osteogenesis via a Capture-Then-Differentiate Framework.

Created on 21 Oct 2026

Authors

Xiaochen Jia, Xiaoshuai Yang, Qihao Wei, Changwen Mi, Teng Lu, Jiabao Pan, Zhongwei Sun

Published in

International journal for numerical methods in biomedical engineering. Volume 42. Issue 10. Pages e70226.

Abstract

Triply periodic minimal surface (TPMS) scaffolds possess significant application potential in bone tissue engineering owing to their smooth and continuous surface morphology and highly interconnected pore networks. However, in conventional parametric modeling of TPMS scaffolds, porosity and pore size usually vary in a coupled manner, restricting the systematic evaluation of scaffold structure-function relationships. In this study, a decoupled single-variable design strategy was adopted to construct homogeneous sheet-based TPMS scaffolds, including diamond sheet (DS), gyroid sheet (GS), and primitive sheet (PS) topologies, with independently controlled porosities (50%-90%) and pore sizes (500-900 μm). A sequential multiphysics framework integrating static compression finite element analysis (FEA), computational fluid dynamics (CFD), the discrete phase model (DPM), and mechano-regulation analysis was established to evaluate osteogenic potential during the early post-implantation hematoma stage. Results demonstrated that porosity primarily governed apparent stiffness, while permeability was highly sensitive to topological changes and pore size enlargement. The initial capture efficiency of mesenchymal stem cells (MSCs) was closely associated with the specific surface area (SSA) and dynamically regulated by flow trajectories and wall accessibility. Furthermore, mechano-regulation stimulus factor analysis, combining wall shear stress (WSS) and octahedral shear strain (OSS), revealed that WSS contributed dominantly to the local osteogenic microenvironment. Osteogenic differentiation efficiency was not maximized by any single structural parameter, but rather emerged from an optimal balance between the capacity to capture MSCs and adequate mechanical stimulation. These findings validate a "capture-then-differentiate" mechanism for early osteogenesis in sheet-based TPMS scaffolds, providing a quantitative multiphysics strategy for the topological optimization of bone scaffolds.

PMID:
42901477
Bibliographic data and abstract were imported from PubMed on 21 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 2
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement