Preparation design and connector geometry influence the mechanical behavior of additively manufactured periodontal splints.

Created on 24 Oct 2026

Authors

Ines Bitri, Karim Nasr, Frédéric Vaysse, Xavier Dusseau, Luc Raynaldy, Sara Laurencin-Dalicieux, Thibault Canceill, Charlotte Thomas

Published in

Journal of dentistry. Pages 107132. Oct 23, 2026. Epub Oct 23, 2026.

Abstract

Structural design guidelines for additively manufactured periodontal splints remain poorly defined, particularly regarding relative influence of preparation and connector geometry.
This in vitro study evaluated the effect of tooth preparation design and connector cross-sectional geometry on the mechanical behavior of these splints, providing preliminary mechanical insights rather than clinical design recommendations.
Standardized specimens were fabricated from a mandibular digital model, combining three preparation designs (no preparation, enamel chamfer finishing line [CFL], and CFL with proximal boxes) with three connector cross-sectional areas (5, 6, and 7 mm²) (n=10 per group; N=90). Specimens were printed by stereolithography using a permanent crown resin and tested under three-point bending (crosshead speed, 1 mm/min). Nominal flexural strength, deformation angle before fracture, and fracture pattern were recorded and analyzed using ANOVA with Bonferroni post hoc tests.
Preparation design significantly influenced nominal flexural strength (p<.001). CFL alone showed the highest flexural strength (65.79 ± 20.98 MPa), significantly greater than no-preparation (27.36 ± 9.51 MPa) and CFL-with-proximal-boxes (29.64 ± 12.20 MPa). Increasing connector area improved performance only within the CFL group, with no difference between 6 and 7 mm² (73.75 ± 13.82 MPa vs. 81.45 ± 10.04 MPa; p>.99). Deformation capacity followed a similar pattern, and fracture mode was primarily determined by preparation design (p<.0001).
Preparation design was a stronger determinant of mechanical behavior than connector dimension alone. CFL combined with connector areas ≥6 mm² was associated with improved performance, though these preliminary findings require validation in more clinically representative models.
Tooth preparation design, particularly a limited enamel chamfer finishing line, combined with connector cross-sectional areas ≥6 mm², was associated with improved mechanical performance under the present experimental conditions. These findings provide preliminary structural design insights for additively manufactured periodontal splints and warrant further validation in clinically representative models.

PMID:
42918480
Bibliographic data and abstract were imported from PubMed on 24 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 13
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement