Measurement Properties of Hand-Held Dynamometry for Ankle Strength Assessment: A COSMIN-Based Systematic Review and Meta-Analysis.

Created on 24 Oct 2026

Authors

Matheus Hissa Lourenço Ferreira, João Victor Völker Oliveira, Nelson Carvas Junior, Túlio Medina Dutra de Oliveira, Guilherme Augusto Santos Araujo, José Elias Filho, George Schayer Sabino, Carla Malaguti, Diogo Carvalho Felício

Published in

Musculoskeletal care. Volume 24. Issue 4.

Abstract

This systematic review and meta-analysis evaluated the measurement properties of handheld dynamometry (HHD) for assessing isometric ankle muscle strength in healthy individuals.
A comprehensive search was conducted in PubMed, EMBASE, CINAHL, Web of Science, SPORTDiscus, PsycINFO, Scopus, and the Virtual Health Library, with no language or date restrictions. Observational and methodological studies assessing dorsiflexors, plantar flexors, invertors, or evertors using HHD were eligible if they reported reliability, measurement error, or construct validity against isokinetic dynamometry. Random-effects meta-analyses were performed by measurement property and testing configuration, following COSMIN guidance.
Twenty-four studies were included. Inter-rater reliability was good for dorsiflexors (ICC = 0.89, 95% CI 0.80-0.94), plantar flexors (ICC = 0.86, 95% CI 0.72-0.93), invertors (ICC = 0.79, 95% CI 0.66-0.87), and evertors (ICC = 0.75, 95% CI 0.46-0.90). Intra-rater reliability ranged from good to excellent (ICC = 0.88-0.91). External fixation was associated with numerically higher inter-rater ICCs for dorsiflexors and plantar flexors although subgroup differences were not statistically significant. Construct validity was strong for dorsiflexors (r = 0.87, 95% CI 0.42-0.98) but uncertain for plantar flexors (r = 0.72, 95% CI -0.20-0.96). Measurement error remained indeterminate due to the absence of an established minimal important change. Certainty of evidence was high for reliability and low for construct validity; measurement error was not graded.
HHD provides reliable assessment of isometric ankle strength, including without external fixation. Evidence for construct validity, particularly for plantar flexors, and for measurement error remains limited.

PMID:
42920374
Bibliographic data and abstract were imported from PubMed on 24 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 11
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement