Harnessing AI for Hypothyroidism Monitoring Using Wearable-Derived Heart Rate Data: Retrospective Cohort Study.

Created on 29 Oct 2026

Authors

Kyubo Shin, Yewon Jung, Won Sang Yoo, Min Joo Kim, Tae Jung Oh, Joon Ho Moon, Sung Hye Kong, Won Woo Lee, Jae Hoon Moon

Published in

JMIR AI. Volume 5. Pages e86030. Oct 28, 2026. Epub Oct 28, 2026.

Abstract

Hypothyroidism is a prevalent endocrine disorder characterized by an insidious onset and nonspecific symptoms, often leading to significant diagnostic delays. While biochemical thyroid function tests (TFTs) are the gold standard, their invasive nature and cost make them impractical for continuous, proactive screening of at-risk populations. Thyroid hormones exert direct chronotropic effects on the cardiovascular system, and their levels are closely correlated with heart rate (HR). Wearable devices capable of continuous HR monitoring offer a novel opportunity for noninvasive, digital phenotype-based detection.
This study aimed to develop and validate an AI-assisted system that uses wearable-derived sleep HR data as a digital monitoring tool for individuals at risk of hypothyroidism, helping identify those who warrant further confirmatory thyroid testing.
This retrospective cohort study used 1677 paired observations consisting of sleep HR data and serum TFT results, including free thyroxine (T4) and thyroid-stimulating hormone levels, from 413 participants (mean age 43.1, SD 9.7 y; women: n=314, 76%). Participants wore consumer-grade wearables (Fitbit) that recorded HR and sleep data. Each TFT result was paired with sleep HR data extracted from the 15 consecutive nights preceding the blood test. An AI system was developed using a gradient boosting algorithm (LightGBM) to classify thyroid status by integrating baseline TFT results with statistical and temporal HR features. The model's performance was evaluated using patient-level leave-one-out cross-validation. To examine the benefit of longitudinal data, performance was compared using 1, 2, or 3 prior paired observations as reference points.
To ensure clinical relevance and avoid performance inflation from hyperthyroid cases, we prioritized the analysis of a subset containing only euthyroid and hypothyroid data (n=744 paired observations). In this clinically challenging subset, the system achieved an accuracy of 74.6%, with a sensitivity of 82% and a specificity of 73.5% using a single-reference data pair. Incorporating longitudinal HR patterns further enhanced performance; using 3 reference pairs improved accuracy to 78.1% (sensitivity 81.8% and specificity 77.7%). In the overall dataset (n=1677 paired observations), the system demonstrated an accuracy of 80.8%, with a sensitivity of 82% and a specificity of 80.8% using a single-reference pair. Notably, the system achieved high clinical safety by detecting 96.3% of severe overt hypothyroidism cases (free T4 <0.5 ng/dL).
This AI-assisted system demonstrates the feasibility of a sensitive, noninvasive longitudinal monitoring tool for hypothyroidism, robustly identifying a high proportion of hypothyroid cases-particularly severe ones-to prioritize at-risk individuals for confirmatory blood tests. Given the predominantly female iatrogenic-withdrawal cohort, prospective sex-balanced validation in primary hypothyroidism is warranted.

PMID:
42950109
Bibliographic data and abstract were imported from PubMed on 29 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 10
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement