Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Optoelectronically synergized MoS2 field-effect transistor sensor for the detection of Alzheimer's disease biomarker Aβ42.

Created on 29 Oct 2026

Authors

Yi Zou, Wenxiang Shi, Fengqiu Jiang, Tao Liu, Zhangcheng Liu, Xiao Wang, Yang Li, Zhiwei Chen, Jin-Ping Ao

Published in

Analytica chimica acta. Volume 1425. Pages 346329. Dec 01, 2026. Epub Sep 26, 2026.

Abstract

Early diagnosis of Alzheimer's disease (AD) relies heavily on the ultra-sensitive detection of its core biomarker, amyloid-beta 42 (Aβ42). To address this critical need, this paper presents a photoelectric synergistically enhanced field-effect transistor (FET) biosensor based on two-dimensional molybdenum disulfide (MoS2) for the highly sensitive and specific detection of Aβ42.
Experimental results demonstrate that light illumination significantly amplifies the sensing current under identical gate voltages and target concentrations. This enhancement enables the device to effectively overcome the subthreshold region and smoothly transition into the linear operating regime at lower voltages, thereby substantially optimizing signal readout efficiency in low-concentration regions. Benefiting from this photoelectric synergy, the sensor exhibits a markedly enhanced signal response and an optimized dynamic range. The limit of detection decreases to 4.15 × 10-18 g/mL, representing a 26.29% reduction compared to dark conditions. Furthermore, the relative standard deviation (RSD) of the current response under illumination improves to 2.47% (n = 3), outperforming the 4.86% recorded in the dark and indicating simultaneous enhancements in detection repeatability and device stability. Supported by Silvaco TCAD simulations, the core operating mechanism is elucidated: the specific binding of target Aβ42 molecules inherently introduces localized interface charge perturbations at the MoS2 channel. This alteration of the interfacial charge state fundamentally governs the electrical response of the device, which is synergistically amplified under light illumination to achieve ultra-high sensing sensitivity.
This study demonstrates that the photoelectric synergistic strategy offers a highly effective pathway to overcome the sensitivity and performance bottlenecks of traditional FET biosensors. Concurrently, it establishes a novel and promising paradigm for the design of high-performance, multimodal photoelectric biomedical diagnostic chips.

PMID:
42951564
Bibliographic data and abstract were imported from PubMed on 29 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 11
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement