Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

RED Protocol: Ultrasound for Intraoperative Detection of Pneumothorax and Hemothorax in Rib Remodeling Surgeries.

Created on 29 Oct 2026

Authors

Hugo A Aguilar, Manuel Velasco, Luis F Reyes, Nicole G Echeverry, Alfredo E Hoyos, Silvia J Villabona, Hector M Serrano, Ricardo Proto, Daniel Oñate Valdivieso, Carlos Oñate Valdivieso, Cristian J Diaz, William Peña-Pinzon, Mauricio Perez, Agustina Varela, Brian Ramirez

Published in

Aesthetic surgery journal. Oct 29, 2026. Epub Oct 29, 2026.

Abstract

Ribcage remodeling procedures are increasingly used in aesthetic surgery to reduce waist circumference; however, they carry a potential risk of pneumothorax and hemothorax due to proximity to the lung parenchyma. Early intraoperative detection of these complications is critical but currently not standardized.
To evaluate the feasibility and diagnostic performance of the Rib Complication Evaluation and Detection (RED) protocol, an intraoperative ultrasound-based approach for detecting pneumothorax and hemothorax during ribcage remodeling procedures.
A retrospective observational study was conducted including 113 patients undergoing ribcage remodeling between 2023 and 2024. Due to the low incidence of pneumothorax, the protocol was additionally assessed using 250 high-fidelity simulation scenarios with the CAE Vimedix system. Ultrasound findings were standardized, and sensitivity, specificity, and predictive values were calculated.
No cases of pneumothorax or hemothorax were identified in the clinical cohort. In simulation testing, the RED protocol demonstrated a sensitivity of 96% and specificity of 100% for pneumothorax detection, with a positive predictive value of 100% and a negative predictive value of 98%. The protocol successfully differentiated pneumothorax from other thoracic conditions.
The RED protocol provides a structured and reproducible approach for intraoperative lung ultrasound in ribcage remodeling. While simulation was necessary due to the low prevalence of complications, the protocol is based on well-established sonographic signs. Its high negative predictive value suggests utility as a rule-out tool, enhancing intraoperative safety. Further prospective studies are needed to validate its performance in real clinical scenarios.

PMID:
42952427
Bibliographic data and abstract were imported from PubMed on 29 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 32
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement