Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Operative efficiency and short-term outcomes of da Vinci 5 versus da Vinci Xi in robotic rectal cancer surgery: an overlap-weighted cohort study with an exploratory case insights analysis.

Created on 01 Nov 2026

Authors

Yasuhiro Ishiyama, Yasumitsu Hirano, Yurie Kitano, Nozomi Yamazaki, Yoshihiro Sakai, Akihito Nakanishi, Yusuke Nishi, Hiroto Tanaka, Hisashi Hayashi, Toru Kuramoto, Takatsugu Fujii, Hirofumi Sugita, Chikashi Hiranuma

Published in

Journal of robotic surgery. Volume 20. Issue 1. Oct 31, 2026. Epub Oct 31, 2026.

Abstract

The da Vinci 5 introduces changes in operative workflow and instrument control, but its comparative performance in rectal cancer surgery remains uncertain. We compared operative efficiency and short-term outcomes after platform introduction and explored platform-derived intraoperative measurements. This retrospective single-center study included 202 patients undergoing robot-assisted rectal cancer surgery from July 2025 to September 2026 (Xi, n = 109; da Vinci 5, n = 93). Propensity-score overlap weighting addressed measured differences. The primary outcome was total operative time. HC3 inference was checked using 2,000 bootstrap replicates with propensity-score re-estimation. Retrieved Case Insights records were summarized descriptively. The adjusted difference in total operative time was - 6.9 min (HC3 95% confidence interval [CI], - 24.4 to 10.6; P = 0.439); the bootstrap 95% CI was - 21.8 to 7.8 min. The adjusted risk difference for Clavien-Dindo grade ≥ II complications was - 9.4% points (HC3 95% CI, - 19.8 to 0.9; P = 0.074). Margin positivity occurred in only three patients and was reported descriptively. Inference for postoperative hospital stay depended on the variance method. We did not detect a statistically clear reduction in total operative time after the introduction of the da Vinci 5. Secondary outcomes remain exploratory. Exploratory Case Insights analysis provided descriptive information on instrument-tip force and surgical workflow, warranting further prospective validation of their clinical relevance.

PMID:
42965763
Bibliographic data and abstract were imported from PubMed on 01 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 6
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement