Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Repeated-cycle operational response and residual fouling characteristics under NaOCl and vanillin-assisted NaOCl backwashing in membrane bioreactors.

Created on 02 Nov 2026

Authors

Jihoon Lee, Sungjin Park, Jihyang Kweon, Wonjung Song

Published in

Environmental technology. Pages 1-12. Nov 01, 2026. Epub Nov 01, 2026.

Abstract

Membrane biofouling remains a major operational constraint in membrane bioreactors (MBRs), increasing transmembrane pressure (TMP) and chemical-cleaning demand. This study compared four backwashing conditions-deionized (DI) water, vanillin-only, sodium hypochlorite (NaOCl)-only, and vanillin-assisted NaOCl backwashing - in lab-scale MBRs over an initial baseline filtration period and four post-backwash filtration cycles, using one independent reactor per condition. Although vanillin has been reported to interfere with quorum sensing, no quorum-sensing-related endpoints were measured in this study. Cumulative operation times were 5.7, 6.9, 14.8, and 13.0 d for DI-water, vanillin-only, NaOCl-only, and vanillin-assisted NaOCl backwashing, respectively. NaOCl alone provided the longest cumulative operation and higher operational-time recovery, defined as post-backwash filtration time relative to baseline filtration time, in Cycles I-II. Vanillin-assisted NaOCl backwashing showed numerically higher recovery in Cycles III-IV (Cycle IV: 31.0% versus 17.0%). Endpoint carbohydrate, protein, and biofilm biomass were lowest under NaOCl-only backwashing. Under vanillin-assisted NaOCl backwashing, total residual carbohydrate and protein were 51.6% and 87.1% of the DI-water values, respectively. Carbohydrate was predominantly soluble, while the soluble-carbohydrate concentration remained below the DI-water value. ATR-FTIR spectra showed attenuated protein-associated bands under both NaOCl-containing conditions. NaOCl alone provided the strongest overall cleaning response within the four-cycle test window. Without independent reactor replication, the later-cycle crossover remains a descriptive observation and does not demonstrate a vanillin-specific effect. Replicated, longer-term evaluation with direct measurements of residual chlorine, parent vanillin and its transformation products, and fouling-layer properties is required.

PMID:
42967307
Bibliographic data and abstract were imported from PubMed on 02 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 14
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement