A lightweight reliability- and confidence-aware selective ECG framework for degraded remote monitoring.

Created on 02 Nov 2026

Authors

Nağme Bilgehan, Bülent Bilgehan

Published in

Computers in biology and medicine. Volume 217. Pages 112025. Nov 01, 2026. Epub Nov 01, 2026.

Abstract

Remote electrocardiogram (ECG) monitoring in Internet of Medical Things (IoMT) systems is vulnerable to sensor noise, missing leads, packet loss, and temporal dropout. The proposed Lightweight Reliability-Aware Internet of Medical Things Electrocardiogram Network (LR-IoMT-ECGNet) is a lightweight reliability-aware framework that couples degradation-aware representation learning with selective decision support. Physikalisch-Technische Bundesanstalt eXtended Large (PTB-XL) electrocardiography dataset version 1.0.3 was used with official folds for training (n = 17,418), validation (n = 2183), and independent testing (n = 2198). Robustness was evaluated under clean, mild, moderate, and severe simulated degradation. A hybrid gate combining predictive confidence and signal reliability was tuned exclusively on validation data and locked before test evaluation. The 24,429-parameter model achieved an area under the receiver operating characteristic curve (AUC) of 0.9188 and F1-score of 0.8449 under clean conditions and an AUC of 0.8683, sensitivity of 0.7753, specificity of 0.8004, and F1-score of 0.8089 under severe degradation. By contrast, clean-trained CNN and ResNet-1D baselines showed near-zero severe specificity (0.0252 and 0.0143). On mixed-quality test data, the hybrid gate retained 90.2% of records and achieved accuracy of 0.8412, sensitivity of 0.8026, specificity of 0.8973, and F1-score of 0.8569 among accepted cases. Confidence-only referral was marginally stronger on some metrics, indicating that predictive confidence is the dominant selective signal while input reliability provides complementary information. The results support a compact, degradation-aware selective ECG framework for edge- or gateway-assisted monitoring, while external wearable validation remains necessary.

PMID:
42967476
Bibliographic data and abstract were imported from PubMed on 02 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 33
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement