Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

A multi-reader multi-case study comparing Breast Cancer Reading Efficiency and Accuracy in Screening with Tomosynthesis versus AI-assisted mammography.

Created on 03 Nov 2026

Authors

Serene Goh Si Ning, Du Hao, Ganga Chandrasegan, Lim Yuan Zheng, Wynne Chua, Han Yang Ong, Edward Seah, Shuliang Ge, Samuel Lau, Ying Mei Wong, Pooja Jagmohan, Hari Trivedi, Beatrice Brown-Mulry, Rohan Satya Isaac, Judy Wawira Gichoya, Aawez Mansuri, Mengling Feng, Bee Choo Tai, Mikael Hartman

Published in

The British journal of radiology. Nov 02, 2026. Epub Nov 02, 2026.

Abstract

Full-field digital mammography (FFDM) is the standard for breast cancer screening but has reduced sensitivity in dense breasts. Digital breast tomosynthesis (DBT) improves cancer detection compared to 2D mammography but is limited by cost and longer reading times. Artificial intelligence (AI)-enhanced mammography has demonstrated improved sensitivity compared to 2D mammography. This study compares AI-enhanced 2D mammography (DM+AI) with DBT in recalling interval breast cancers (IBCs).
: A multi-reader, multi-case crossover study was conducted using the Emory BrEast Imaging Dataset, which includes paired FFDM and DBT images with biopsy-proven outcomes. Six radiologists reviewed 53 IBC and 53 screen-detected cancer (SDC) cases, with random assignment to DM+AI or DBT, followed by crossover after a washout period. Primary outcomes included recall rate of IBCs. Secondary outcomes included recall rate of SDCs, interpretation time, and subgroup analysis by breast density.
: For IBCs, DM+AI and DBT demonstrated similar recall rates (41.5% vs 40.9%) and detection rates (14.8% vs 11.9%). DM+AI identified more non-invasive (31.5% vs 13.0%) and mass-forming (61.0% vs 21.8%) cancers. For SDCs, recall and detection rates were comparable across modalities. In fatty breasts, recall was higher with DM+AI (91.7% vs 50.0%), while DBT performed better in extremely dense breasts. DM+AI enabled faster interpretation, averaging 24.1 seconds less per case.
: AI-enhanced 2D mammography demonstrated comparable performance to DBT with shorter interpretation times, supporting a stratified screening approach.
This study is the first direct comparison of AI-enhanced mammography and digital breast tomosynthesis for IBC detection.

PMID:
42973140
Bibliographic data and abstract were imported from PubMed on 03 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement