Transcutaneous Pacing in the Prehospital Setting - A Retrospective Cohort Study of Electrical Capture.

Created on 04 Nov 2026

Authors

Meghan N Hershkowitz, Lianne J Kniest, Peter Davis-Allen, Ikram A Mohamed, Catherine R Counts, David L Murphy, Robert G Walker, Tyson G Taylor, Doan Dinh, Charles C Maynard, Peter J Kudenchuk, Thomas D Rea, Michael R Sayre

Published in

Prehospital emergency care. Pages 1-16. Nov 03, 2026. Epub Nov 03, 2026.

Abstract

Transcutaneous pacing (TCP) treats hemodynamically unstable bradycardia refractory to pharmacologic management. Effective TCP requires electrical and mechanical capture to augment perfusion. Little is known about prehospital TCP and capture incidence.
We conducted a retrospective cohort study of patients treated with prehospital TCP by an emergency medical services agency between 2017 and 2024. Continuous ECG recordings from cardiac monitors were reviewed. Electrical capture was the primary outcome, defined as a widened QRS with a distinct T wave following a TCP spike. Secondary measures included capture duration, clinician-verbalized pulse during pacing, plethysmograph waveform alignment, and changes in systolic blood pressure (SBP), pulse oximetry, and end-tidal carbon dioxide.
Fifty-six patients received attempted TCP. Median age was 70 years (interquartile range [IQR] 58-85), and 34% were female. Cardiopulmonary resuscitation (CPR) was administered in 59% of patients. Electrical capture was achieved in 18 patients (32%). Among patients who achieved electrical capture, complete capture occurred a mean of 27.2% (standard deviation 30.5%) of attempted pacing duration. The median SBP change was +22.0 (IQR: -2-82) mmHg in patients with electrical capture and 0.0 (IQR: -29-7) mmHg in those with only rare-to-absent capture (p = 0.031). During TCP, clinicians verbalized a palpable pulse 26 times across 19 patients. Only 4 instances (15%) coincided with electrical capture.
Electrical capture during prehospital TCP occurred in a minority of patients and was often intermittent. Prehospital identification of mechanical capture using routine clinical indicators was difficult and unreliable. Future work should standardize capture definitions and physiologic measurements to determine when TCP produces clinically meaningful perfusion.

PMID:
42976244
Bibliographic data and abstract were imported from PubMed on 04 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 34
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement