Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Automated Detection of Positioning Errors in Bitewing Radiographs Using Deep Learning.

Created on 05 Nov 2026

Authors

Katharina Alves Rabelo, Zimo Huang, Eduardo Delamare, Shwetha Hegde, Jinman Kim, Vesna Miletic

Published in

Clinical and experimental dental research. Volume 12. Issue 6.

Abstract

Bitewing radiographs (BWs) are essential diagnostic tools in dentistry, but are often affected by positioning errors, compromising their diagnostic value and increasing retake rates. This study aimed to develop and evaluate a deep learning-based automated system for detecting and classifying BW type (premolar/molar), side (right/left), and common positioning errors in a controlled mannequin-based setting.
A total of 403 BWs were collected from dental student assessments acquired from dental radiology mannequins. BWs were consensus-labeled by dentomaxillofacial radiology experts for type, side, and the most common positioning errors. A balanced data set supported training and validation. Convolutional neural network architectures, including ResNet and DenseNet variants, were trained from scratch and evaluated as independent classification tasks using stratified fivefold cross-validation. Performance was assessed using accuracy, precision, recall, F1 score, and area under the curve, reported as mean ± standard deviation across folds. A confusion matrix was generated for multi-class cone-cutting error (CCE) severity classification.
The system achieved accuracies of 95.8% for BW type classification, 99.0% for side classification, 96.3% for CCE detection, and 93.4% for interproximal overlap detection. Multi-class CCE classification achieved an accuracy of 79.3%, with reliable identification of "critical" and "minimal" errors. Detection of incorrect receptor placement achieved an accuracy of 73.2%.
The CNN-based system showed strong performance for bitewing type, side, binary cone-cutting error, and interproximal overlap classification in mannequin-acquired radiographs. Performance was more limited for multi-class cone-cutting severity and incorrect receptor placement. These findings support the potential use of deep learning for radiographic quality assessment in education and quality-control workflows. A validation study using patient-acquired bitewing radiographs from clinical settings is required before clinical deployment.

PMID:
42981213
Bibliographic data and abstract were imported from PubMed on 05 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 10
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement