Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Development of a Gas Chromatographic Method for Determination of CO2/CH4 Breakthrough Curves in Fixed-Bed Adsorption.

Created on 06 Nov 2026

Authors

Tamille A Souza, Mirtes F S Freitas, Argenis A S Jimenez, Yanier S Hechavarria, Raildo A Fiuza-Júnior, Artur J S Mascarenhas, Karen V Pontes

Published in

Journal of separation science. Volume 49. Issue 11.

Abstract

Adsorption stands out as a promising alternative for CH4/CO2 separation of biogas and natural gas. The design of fixed-bed columns depends on laboratory-scale breakthrough curve assays, which require fast-response analytical methods such as microchromatographs or gas analyzers. However, these instruments are not always available in research laboratories, where conventional gas chromatography (GC) represents a more accessible alternative. Nevertheless, conventional GC generally does not achieve analysis times on the order of seconds. In this context, this work aims to develop and refine a chromatographic method based on conventional GC to obtain breakthrough curves for CO2/CH4 mixtures in a fixed-bed reactor, with reduced data-acquisition time. A chromatographic method was developed for constructing breakthrough curves using a two-level factorial design, achieving a chromatographic cycle time of approximately 4.5 min while maintaining adequate CO2/CH4 separation. The method demonstrated linearity within the evaluated concentration ranges, with low limits of quantification and detection, and was precise and robust. A sequential injection strategy was implemented to acquire chromatographic data during continuous-flow breakthrough experiments. The method was tested and evaluated with different adsorbents (zeolite and activated carbon), successfully reproducing CO2/CH4 breakthrough profiles and enabling the determination of dynamic adsorption capacity and selectivity. These results validate the proposed method's analytical performance and applicability under realistic separation conditions. Overall, the proposed approach provides a robust, accessible, and easily implementable strategy for breakthrough curve determination using widely available GC configurations, offering a practical alternative for laboratories lacking fast-response analytical systems.

PMID:
42989915
Bibliographic data and abstract were imported from PubMed on 06 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 11
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement