Authors
Y Ohtani, H Sakai, H Sasao
Published in
The Review of scientific instruments. Volume 97. Issue 11. Nov 01, 2026.
Abstract
Density profile reconstruction and fringe-jump correction using a toroidal interferometer and polarimeter with a limited number of chords have been developed to reduce the number of diagnostic ports in future devices. The density profile reconstruction method exploits the fact that the line of sight through the high-field side can be treated as two effective lines of sight (LOSs) due to the magnetic field geometry. The reconstruction is based on Gaussian process regression and Markov chain Monte Carlo sampling. For a single LOS without significant gradient variation, the coefficient of determination R2 exceeds 0.9, where a value closer to unity indicates better reproduction of the profile. For density profiles with steep gradient variation, although three LOSs are required, the reconstruction accuracy surpasses that of interferometry with the same number of chords. A fringe-jump correction method exploits the fact that the temporal evolution of the density is preserved even when the absolute density from the interferometer is lost. Assuming a linear density change, the estimated line-integrated density improves from 88.9% to 92.1% of the true value compared with the polarimeter-only reconstruction. If the interferometer error is ten times smaller than the polarimeter error, the improvement reaches 96.6%.
PMID:
43002107
Bibliographic data and abstract were imported from PubMed on 09 Nov 2026.