Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Fluorinated antifouling imprinted polymer platform for electrochemical selective detection of perfluoroalkyl and polyfluoroalkyl substances.

Created on 10 Nov 2026

Authors

Xiaoyu Zhu, Jiawen Li, Chen Cheng, Zhong Ren, Ying Wang

Published in

Analytica chimica acta. Volume 1427. Pages 346395. Dec 15, 2026. Epub Oct 15, 2026.

Abstract

Perfluorooctane sulfonates (PFOS) commonly coexists with other PFAS in aquatic matrices, making selective recognition challenging in complex water samples. In this study, we developed a fluorination-engineered surface molecularly imprinted electrochemical sensor (Po-PD-F SMIP) for the highly selective detection of PFOS. The sensing layer was formed by electropolymerizing o-phenylenediamine on a PFDT-functionalized interface. PFOS was selectively captured through synergistic spatial matching within the MIP cavities and fluorinated interface interactions between the perfluorinated chains of PFOS and PFDT. The PFDT-containing interface also provided antifouling behavior through fluorinated interfacial while maintaining electron-transfer pathways. PFOS rebinding caused a pronounced decrease in the differential pulse voltammetry (DPV) response of the [Fe(CN)6]3-/4- redox probe owing to competitive adsorption and hindered electron transfer. The optimized sensor exhibited excellent linearity over a wide dynamic range from 0.05 ng mL-1 to 500.1 μg mL-1 (R2 = 0.9903), with a low limit of detection (LOD) of 12.1 ng L-1. Compared with the Po-PD sensor, incorporation of the PFDT probe increased the imprinting factor by 2.43-fold and enhanced the binding affinity by approximately 102.8-fold. The sensor exhibited an IF of 11.99 for PFOS, 4.28-8.75 times higher than those for other perfluorinated analogues. It was also successfully applied to real water samples, with satisfactory recoveries and good agreement with LC-MS/MS results. This study provides a promising approach for rapid, sensitive, and reliable on-site monitoring of trace PFOS in complex water samples.

PMID:
43003588
Bibliographic data and abstract were imported from PubMed on 10 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement