In vivo dosimetry (IVD) is essential for verifying treatment accuracy and current methods only identify discrepancies after delivery. Predicting IVD results beforehand offers proactive risk anticipation. This study aimed to develop a machine learning (ML) model for predicting electronic-portal-imaging-device (EPID)-based IVD results. Input predictors included volumetric modulated arc therapy (VMAT) plan complexity metrics, gamma passing rate (GPRs) from EPID-based patient-specific quality assurance (PSQA), and daily machine output quality assurance (QA) data for each treatment fraction. Seventeen VMAT plan complexity metrics were calculated from DICOM-RT files, and GPRs were obtained from forty head and neck cancer patients. The IVD results, a set of point-dose deviations between reconstructed and planned dose distributions, served as the input response. An ensemble-bagged-tree regression model was used to develop the prediction model. Model performance was evaluated using root mean square error (RMSE), mean absolute error (MAE), and R-squared. Spearman's rank correlation assessed relationships between predictors and responses. In the test set, the model achieved RMSE of 2.9%, MAE of 2.1%, and R-squared of 0.80. Correlations between EPID-based IVD results and plan complexity, GPRs of PSQA, and machine output QA metrics were weak, while the ML model showed strong predictive accuracy, closely matching predicted and measured IVD results. This study demonstrates the feasibility of combining ML with EPID-based IVD point-dose data. If further developed, this approach could provide fraction-by-fraction IVD estimates in clinics without dedicated IVD software and enable early detection of potential errors, enhancing IVD process.

PMID:
43007600
Bibliographic data and abstract were imported from PubMed on 11 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 18
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement