Tricuspid inflow E-wave velocity for the assessment of severe or greater tricuspid regurgitation: derivation and external validation of threshold values.

Created on 11 Nov 2026

Authors

Samantha Fisicaro, Madalina-Patricia Moldovan, Yuka Kawada, Marco Penso, Matheus Simonato, Alexandra Simona Buta, Andra Negru, Alexandra Clement, Paolo Springhetti, Noela Radu, Francesca Heilbron, Michele Tomaselli, Valeria Rella, Denisa Muraru, Rebecca T Hahn, Luigi P Badano

Published in

European heart journal. Cardiovascular Imaging. Nov 10, 2026. Epub Nov 10, 2026.

Abstract

Current guidelines include tricuspid inflow E-wave (>100 cm/s by pulsed-wave Doppler) as a semiquantitative criterion for diagnosing severe tricuspid regurgitation (TR), despite limited supporting evidence. We assessed its diagnostic performance for identifying severe or greater TR, deriving and externally validating practical thresholds.
Tricuspid inflow E-wave velocity was measured by pulsed-wave Doppler in consecutive patients with at least mild TR between December 2024 and February 2026. Among 178 patients (77±13 years, 65% women), TR was mild in 44, moderate in 61, severe in 44, massive in 15, and torrential in 14. Mean tricuspid E-wave velocity was 56±16 cm/s and increased with TR severity: 47±8, 50±10, 62±16, 67±13, and 77±21 cm/s for mild, moderate, severe, massive, and torrential TR. Only three patients had E-wave velocity >100 cm/s (one with severe and two with torrential TR). Using multiparametric echocardiographic grading as the reference standard, the >100 cm/s threshold showed 5.5% sensitivity, 100% specificity, and kappa 0.25 for severe or greater TR. As a continuous variable, E-wave velocity discriminated severe or greater TR with an AUC of 0.81. A lower threshold of 52 cm/s yielded 81% sensitivity and 67% specificity, whereas 47 cm/s provided 90% sensitivity and 43% specificity. External validation resulted in 94% sensitivity and 47% specificity.
The guideline-recommended threshold of >100 cm/s is highly insensitive for detecting severe or greater TR. Lower cut-offs, particularly 47 cm/s, may be useful for screening to trigger a comprehensive multiparametric assessment.

PMID:
43008201
Bibliographic data and abstract were imported from PubMed on 11 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 14
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement