Influence of key operational parameters on harmonic signals in WMS-TDLAS: a simulation study.

Created on 11 Nov 2026

Authors

Xiaofan Du, Xiting Yang, Xiaofei Hao, Yangyang Du, Leizi Jiao, Daming Dong, Cuiping Yao

Published in

Applied optics. Volume 65. Issue 32. Pages 11169-11181. Nov 10, 2026. Epub Oct 12, 2026.

Abstract

Tunable diode laser absorption spectroscopy (TDLAS) combined with wavelength modulation spectroscopy (WMS) is widely used for trace-gas sensing. This study presents a reproducible numerical analysis of the effects of gas concentration, pressure, temperature, lock-in reference phase, and modulation index on first- and second-harmonic signals. The model combines the Beer-Lambert law, the complete HITRAN temperature-dependent line-strength expression, pressure- and temperature-dependent Lorentzian linewidths, and time-domain dual-phase lock-in demodulation. Simulations were performed for a specified methane transition and baseline parameter set under weak-absorption conditions. The signed first-harmonic quadrature extremum and phase-independent second-harmonic magnitude increase linearly with concentration over the investigated range. The temperature response is transition-specific and results from the combined effects of line strength, molecular number density, linewidth, and modulation conditions. Pressure effects are evaluated separately for fixed frequency-modulation amplitude and fixed modulation index to distinguish linewidth-induced changes from changes in modulation depth. The signed in-phase and quadrature components vary with the reference phase, whereas the dual-phase harmonic magnitude is phase independent. The 1f and 2f responses show different dependences on the modulation index, with the 2f response reaching a maximum near m=2.2 under the present conditions. The numerical implementation was independently benchmarked against direct Fourier coefficients and assessed through sampling- and filter-parameter convergence tests. These results provide a validated numerical reference for interpreting parameter-dependent WMS-TDLAS responses within the stated model assumptions.

PMID:
43008143
Bibliographic data and abstract were imported from PubMed on 11 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement