Finding the weak spot: a new approach to locate unstable sites prone to conduction block in heterogeneous cardiac tissue.

Created on 11 Nov 2026

Authors

Alessio Ostini, Helene Hinnen, Jan P Kucera

Published in

Journal of molecular and cellular cardiology. Nov 10, 2026. Epub Nov 10, 2026.

Abstract

Safe and stable action potential propagation is crucial for the proper function of the heart. Altered propagation safety can lead to slow conduction and conduction block, the key ingredients of reentrant and potentially life-threatening arrhythmias. Hence, it is important to develop metrics to quantify the stability of conduction. The previously proposed safety factor, useful in computer simulations, is difficult to determine in real cardiac tissue. We hypothesized that unstable conduction, potentially prone to block, is sensitive to small perturbations of pacing and tested this in co-cultured strands of homozygous connexin 43 knock-out and heterozygous knock-out or wild-type murine ventricular cardiomyocytes grown on microelectrode arrays, and in corresponding computer simulations. The tissues were stimulated at a progressively increasing rate in the presence vs absence of stochastic or alternating variations of pacing cycle length. Variations of conduction times between adjacent electrodes were analyzed using principal components analysis. In 18 out of 19 cultured strands and in 10 out of 10 simulations, our approach correctly identified and predicted the location at which conduction block ultimately occurred already hundreds of beats and tens of seconds in advance. Interestingly, prediction was already possible in the absence of pacing variations, albeit with lower reliability. Finally, the site of slowest conduction was not necessarily the site of block. By permitting to identify sites of unstable conduction most prone to block occurs, our work may find translational applications in clinical cardiac electrophysiology during mapping and ablation procedures and open new avenues to explore innovative markers of conduction stability.

PMID:
43009048
Bibliographic data and abstract were imported from PubMed on 11 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 10
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement