Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Overview of the 2025 FDA circulatory systems devices panel advisory committee meeting on the V-Wave Ventura Interatrial Shunt System.

Created on 11 Nov 2026

Authors

Ori Waksman, Edward Ha, Asa Phichachop, Ron Waksman

Published in

Cardiovascular revascularization medicine : including molecular interventions. Oct 22, 2026. Epub Oct 22, 2026.

Abstract

Interatrial shunting is a novel strategy to reduce left atrial pressure and heart-failure (HF) morbidity. The Ventura Interatrial Shunt System (V-Wave) was evaluated in the randomized, sham-controlled RELIEVE-HF trial and reviewed by the U.S. Food and Drug Administration (FDA) Circulatory Systems Devices Panel.
To summarize the scientific and regulatory deliberations among the sponsor, FDA, and Advisory Panel regarding the safety, effectiveness, and benefit-risk profile V-Wave.
We reviewed publicly available FDA documents, sponsor presentations, FDA analyses, and Advisory Panel discussions from the December 2025 meeting, with emphasis on trial design, endpoint selection, subgroup interpretation, and regulatory standards.
The sponsor emphasized reductions in recurrent HF events among patients with HF with reduced ejection fraction (HFrEF), supported by prespecified recurrent-event analyses and echocardiographic data, while arguing that the hierarchical win-ratio primary endpoint underestimated benefits. In contrast, the FDA highlighted the failure to meet the prespecified primary endpoint in the intention-to-treat population, the fragility of subgroup findings, lack of outcome improvement, and consistent harm in patients with preserved ejection fraction. Advisory Panel members acknowledged acceptable procedural safety but expressed concern regarding the absence of clear, reproducible efficacy, challenges in phenotype-based labeling, and the inability of post-approval registries to resolve evidence gaps.
The Advisory Panel unanimously concluded that, despite procedural safety, the evidence did not demonstrate a favorable benefit-risk profile for the V-Wave device. The deliberations underscore the challenges of relying on subgroup analyses, recurrent-event endpoints, and post-market data to support approval of permanent intracardiac devices in this population.

PMID:
43009431
Bibliographic data and abstract were imported from PubMed on 11 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 19
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement