Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Lab-in-a-Tube System Integrating Hierarchically Wrinkled Electrodes and DNAzyme-Functionalized Beads for Diagnosis of Clostridioides difficile Infection.

Created on 13 Nov 2026

Authors

Survanshu Saxena, Soyeon Lee, Youngeun Choi, Jonathan L'Heureux-Hache, Jiaying Liu, Sadman Sakib, Sara M Imani, Marek Smieja, Yingfu Li, Todd Hoare, Leyla Soleymani

Published in

Advanced materials (Deerfield Beach, Fla.). Volume 38. Issue 56. Pages e74907. Epub Sep 05, 2026.

Abstract

The diagnosis of bacterial infections remains slow because many existing methods rely on enrichment steps such as nucleic acid amplification or growth culture. RNA-cleaving DNAzymes offer a promising route to accelerate bacterial diagnosis because they can be selected and programmed to specifically recognize disease-causing bacteria and generate reporter DNA strands for signal readout. However, integrating DNAzymes into biosensors capable of analyzing complex biological matrices remains challenging, as matrix-associated interferents can destabilize DNAzymes, suppress catalytic activity, and compromise signal detection. Here, we integrate redox RNA-cleaving DNAzymes housed on antifouling magnetic beads with a lab-in-a-tube platform that incorporates hierarchically structured sensing electrodes within a tubular flow cell for enrichment-free detection of Clostridioides difficile in stool samples. The combination of antifouling magnetic beads and fluidic replenishment of DNA reporters across the hierarchical electrodes reduces nonspecific binding and enhances reporter capture efficiency, achieving a limit of detection as low as 1.3 × 102 CFU mL-1 in buffer. Using an optimized stool-processing procedure, the sensor enabled detection of C. difficile infection in 38 human stool samples, demonstrating 94.7% concordance with the current gold-standard polymerase chain reaction method. These results demonstrate a promising platform for enrichment-free, point-of-care diagnosis of infectious diseases in clinic settings.

PMID:
42700408
Bibliographic data and abstract were imported from PubMed on 13 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 10
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement