Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Pre-puncture EUS-based prediction of technical failure during EUS-guided hepaticogastrostomy: development and internal validation of a three-factor model.

Created on 13 Nov 2026

Authors

Takeshi Ogura, Saori Ueno, Nobu Nishioka, Takafumi Kanadani, Masahiro Yamamura, Junichi Nakamura, Nobuhiro Hattori, Kimi Bessho, Takahito Sagawa, Kentaro Osaka, Naoto Aoyama, Hiroki Nishikawa, Nga Nguyen Trong, Ahmad F Aboelezz, Yi-Jun Liao, Szu-Chia Liao

Published in

Gastrointestinal endoscopy. Nov 12, 2026. Epub Nov 12, 2026.

Abstract

Technical failure during EUS-guided hepaticogastrostomy (EUS-HGS) remains clinically relevant, yet most previously reported predictors are assessed only after bile duct puncture or guidewire manipulation has already been attempted. We aimed to identify EUS-assessable anatomical factors measurable before bile duct puncture and to develop an internally validated model for predicting first-attempt technical failure during EUS-HGS.
We retrospectively analyzed consecutive patients who underwent attempted EUS-HGS between January 2015 and December 2025 at a single tertiary center. The primary outcome was first-attempt technical failure of EUS-HGS. Pre-puncture EUS images were reviewed to measure bile duct diameter at the intended puncture site, needle-duct angle, and hepatic parenchymal length. Independent predictors were identified using multivariable logistic regression, and a three-factor prediction model was developed. Discrimination, calibration, and internal validation with 2,000 bootstrap resamples were assessed.
Among 453 attempted EUS-HGS procedures, first-attempt technical success was achieved in 400 (88.3%) and first-attempt technical failure occurred in 53 (11.7%). Smaller bile duct diameter (OR 0.282 per 1-mm increase; 95% CI 0.181-0.440), a more acute needle-duct angle (OR 0.632 per 10° increase; 95% CI 0.533-0.748), and longer hepatic parenchymal length (OR 1.144 per 1-mm increase; 95% CI 1.080-1.212) were independently associated with first-attempt technical failure. The combined three-factor model showed excellent apparent discrimination (AUC 0.932; 95% CI 0.897-0.961), with an optimism-corrected AUC of 0.927 after bootstrap validation. The optimal cutoff probability was 0.130, yielding 86.8% sensitivity and 85.5% specificity. Observed failure rates were 1.7% in the low-risk group, 9.0% in the intermediate-risk group, and 51.9% in the high-risk group.
A three-factor model based on anatomical variables assessable on EUS before bile duct puncture showed excellent apparent discrimination and good calibration for predicting first-attempt technical failure during EUS-HGS. This internally validated model provides a preliminary framework for pre-puncture risk estimation; however, its clinical application remains hypothesis-generating and requires prospective multicenter external validation before implementation in clinical decision-making.

PMID:
43020139
Bibliographic data and abstract were imported from PubMed on 13 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 19
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement