Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

[Endovascular Aortic Repair (EVAR): Intravascular Ultrasound (IVUS) Procedures Compared to X-ray Procedures - a Retrospective Mono-centre Pilot Study].

Created on 13 Nov 2026

Authors

Rafat A Atawneh, Wolfram von Bernstorff, Stephan Kersting, Andreas Hoene, Ali Aghdassi, Sven Speerforck, Jörg Teßarek

Published in

Zentralblatt fur Chirurgie. Nov 12, 2026. Epub Nov 12, 2026.

Abstract

Endovascular aortic repair (EVAR) is the most common procedure to treat abdominal aortic aneurysms and employs X-rays and contrast medium to visualise arteries. However, both X-rays and contrast agents bear considerable hazards, not only for patients, but for the surgical staff, too. In this monocentric pilot study, the impacts of intra-vascular ultrasound (IVUS) on quality and safety were examined, together with the dose of radiation and contrast agent.
From 2017 to 2022, a total of 59 patients were retrospectively included, using intravascular ultrasound. 52 men (88%) and 7 women (12%) were compared, with a historic group employing standard EVAR. The group of 59 patients was then divided into 2 groups: one with procedures including IVUS, radiation and contrast agents, the other one excluding contrast agents.
The historical group and the IVUS group did not differ with respect to patient data and results, but the dose of radiation was drastically reduced in the IVUS group. Comparing groups 1 and 2 of the IVUS group, there were no statistically significant differences with regard to gender, age, BMI, anaesthesia, diameter of the aneurysm, angulation of the neck, or symptoms, p > 0.05. Moreover, the amount of endoleaks (1a/b, 3, 4), mortality as well as complication rates did not differ, p > 0.05. However, significant differences could be demonstrated for the dosage of radiation (dose area product [DAP] group 1 53704 mGy ∙ cm2 [9036-312669] versus group 2 26653 mGy ∙ cm2 [1074-118825], p < 0.001), time of surgery (85.96 min [28-194] versus 69.60 min [27-96], p = 0.026), time of radiation (10.60 min [1-29.12] versus 7.05 min [0.48-24.37], p = 0.003), and amount of contrast medium (27.21 ml [7-65] versus 0 ml, p < 0.001).
EVAR employing IVUS and X-ray was shown to be as safe as standard EVAR regarding procedure quality and patient outcome. However, the dosage of radiation as well as contrast agent can be significantly reduced, decreasing health hazards for patients and surgical staff. Therefore, the use of IVUS for EVAR is strongly recommended for all centres of vascular surgery.

PMID:
43020125
Bibliographic data and abstract were imported from PubMed on 13 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 6
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement