Indoor air quality and particulate matter exposure in early childhood centres under natural ventilation and air-conditioned operation in Lampang, Thailand.

Created on 13 Nov 2026

Authors

Pantitcha Thanatrakolsri, Butsabamintra Labutdi, Sawanya Khumsuk, Kanchana Khamphakhiao

Published in

Dialogues in health. Volume 9. Pages 100369. Epub Nov 02, 2026.

Abstract

Air pollution, particularly fine and coarse particulate matter including PM2.5 and PM10, poses an important health concern for young children. This cross-sectional observational study characterised indoor air quality and particulate exposure in early childhood development centres under routine non-haze conditions, comparing morning natural-ventilation periods with afternoon air-conditioned periods. PM2.5 and PM10 measurements were used to estimate 5-h time-weighted average concentrations (TWA5h), inhaled particulate mass, and body-weight-normalised exposure doses among children aged under 3 years. A scenario-based analysis compared the observed mixed daily operating schedule with hypothetical conditions of continuous natural ventilation and continuous air-conditioned operation. PM2.5 concentrations were lower during the afternoon air-conditioned period than during the morning natural-ventilation period across all eight comparison units, while PM10 concentrations were lower in seven comparison units but higher in one. Mean CO2 concentrations were higher during the afternoon air-conditioned period across all eight comparison units. Estimated PM10 doses exceeded PM2.5 doses across all centres, and scenario-based estimates showed more consistent reductions for PM2.5 than for PM10 under continuous air-conditioned operation. Because ventilation condition coincided with time of day and outdoor particulate measurements were incomplete, the observed differences cannot be attributed solely to ventilation condition or specific particle sources. These findings indicate that indoor air-quality management should jointly address particulate control and adequate outdoor-air provision, together with filtration, indoor source control, and regular system maintenance.

PMID:
43022958
Bibliographic data and abstract were imported from PubMed on 13 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 14
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement