Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Restoring Arterial Pulsatility via Speed Modulation in Ventricular Assist Devices: A Structured Narrative Review and Mechanistic Windkessel-Based Analysis.

Created on 14 Nov 2026

Authors

Peng Fang, Zhongqi An, Haiquan Feng, Rundong Wang, Yating Zhang, Jinbo Wang

Published in

Artificial organs. Nov 13, 2026. Epub Nov 13, 2026.

Abstract

Continuous-flow ventricular assist devices (CF-VADs) attenuate arterial pulsatility, potentially predisposing patients to complications such as endothelial dysfunction and gastrointestinal bleeding. Speed modulation has been proposed to reconstruct arterial pulsatility, but its effectiveness and underlying mechanisms remain incompletely understood.
A structured narrative review was conducted using studies identified from PubMed, Scopus, and Web of Science through June 2026. Evidence from animal experiments, mock circulatory loop studies, lumped-parameter models, and clinical investigations was synthesized. A Windkessel-based framework was used to interpret the effects of modulation parameters on arterial pulsatility.
Animal and computational studies generally demonstrate that speed modulation can enhance arterial pulsatility, with the enhancement depending on factors such as modulation amplitude, waveform, frequency (i.e., the duration of high- and low-speed phases) and phase relationship. Windkessel-based analysis further indicates that pulsatility enhancement is governed by differences in flow-time integrals between modulation phases, providing a mechanistic explanation for the observed effects of modulation parameters. However, clinically implemented speed modulation algorithms have not consistently produced significant improvements in arterial pulsatility or vascular function.
Speed modulation can enhance arterial pulsatility under animal and computational conditions, but its clinical effectiveness remains limited. This discrepancy may reflect constraints on modulation amplitude and duration imposed by hemocompatibility, ventricular safety, and device reliability. Future research should integrate multiscale hemodynamic and hemocompatibility assessments, long-term animal and clinical validation, and advanced device designs and control strategies.

PMID:
43031307
Bibliographic data and abstract were imported from PubMed on 14 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 3
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement