Authors
Ryuichi Asai, Jesse Yu Tajima, Kento Terasaki, Ryoma Yokoi, Keita Matsumoto, Masahiro Fukada, Yuta Sato, Itaru Yasufuku, Yoshihiro Tanaka, Nobuhisa Matsuhashi
Published in
Surgical case reports. Volume 12. Issue 1. Epub Nov 10, 2026.
Abstract
Situs inversus totalis (SIT) is a rare congenital anomaly characterized by a complete mirror-image reversal of organs. Especially in a minimally invasive surgery, care must be taken to avoid misidentification because of reversed anatomical landmarks. Robot-assisted surgery (RAS) may be a feasible surgical option and may facilitate precise surgical manipulation in anatomically challenging situations. Although there are several reports of RAS using the da Vinci surgical robot system (Intuitive Surgical, Sunnyvale, CA, USA) for colorectal cancer (CRC) in patients with SIT, the optimal robot platform, port settings, and procedures have not been determined.
In a 74-year-old woman with SIT referred to our department for treatment of advanced rectal cancer, preoperative examinations showed cancer invasion beyond the intestinal walls and multiple lymph node swelling within the mesentery. After completing 4 cycles of preoperative chemotherapy, robot-assisted low anterior resection using the hinotori™ surgical robot system (hinotori; Medicaroid, Kobe, Hyogo, Japan) was planned. Prior to the surgery, we conducted meticulous simulation with other medical staff using the hinotori, instruments, monitors, and a dry box. During the operation, port placements and instruments were set in a completely left-right reversed position from the standard configuration. From the medial approach through mesenteric vessel division and dissection of the left-sided colon and rectosigmoid junction, the cockpit surgeon smoothly operated monopolar curved scissors with the non-dominant left hand with reversed procedures. In the operating room, a monitor displaying a left-right flipped image was placed alongside the original-image monitor, and surgery proceeded while the patient-side surgeons confirmed anatomical accuracy. As the hinotori has no sealing devices or linear staplers, vessel ligation, division of the mesorectum, and rectal transection were performed by the patient-side surgeons. The patient was discharged without major complications.
To our knowledge, this is the first report of a surgical robot system other than the da Vinci system used to perform surgery for CRC in a patient with SIT. Sufficient preoperative simulation and display of flipped images contributed to the safe operation of robot-assisted low anterior resection in the patient. It is necessary to understand the characteristics of each surgical robot platform and perform surgery by leveraging the system's individual features.
PMID:
43036759
Bibliographic data and abstract were imported from PubMed on 16 Nov 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 6
- Comments 0