Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Pupillary and Oculomotor Responses to Conventional Near Viewing and a Long-Distance Optical Imaging Workbench in Children.

Created on 16 Nov 2026

Authors

Shuo Wu, Yumeng Li, Hao Fu, Wanting Liu, Kai Wang

Published in

Clinical optometry. Volume 18. Pages 658147. Epub Nov 11, 2026.

Abstract

To compare binocular pupil diameter and selected oculomotor measures during far viewing (Far), conventional near viewing (Near), and viewing through a long-distance optical imaging workbench (LOIW) in children.
Of 86 children enrolled in this single-center repeated-measures study, three were excluded because of missing eye-tracking data; data from 83 children aged 8 to 15 years were analyzed. Children fixated a stationary cross in the fixed sequence of Far, Near, and LOIW. After two minutes of adaptation, children viewed the target for one minute, with a 10-second recording obtained once fixation appeared stable. Conditions were separated by one minute of rest. Measured illuminance was the same for Near and LOIW. Pupil diameter was analyzed using a linear mixed-effects model with a random intercept for each participant. Exploratory paired comparisons of fixation duration, saccade amplitude in pixels, and software-reported saccade frequency were adjusted using Holm's method across nine tests.
Mean pupil diameter was 4.87 ± 0.71 mm during Far, 2.93 ± 0.54 mm during Near, and 4.23 ± 0.69 mm during LOIW. The mean difference in pupil diameter between LOIW and Near was 1.30 mm (95% CI, 1.12 to 1.48; Holm-adjusted P < 0.001). Compared with Near, LOIW was associated with longer fixation duration (difference, 19.61 ms; 95% CI, 14.56 to 24.67; adjusted P < 0.001) and greater saccade amplitude in pixels (difference, 10.77 px; 95% CI, 4.48 to 17.06; adjusted P = 0.005). Software-reported saccade frequency did not differ significantly among conditions.
LOIW viewing was associated with larger pupils, longer fixation duration, and greater saccade amplitude in pixels than Near viewing. The fixed viewing order, target magnification, and unmeasured target luminance limit interpretation. These findings do not establish reduced accommodation, improved visual comfort, or efficacy in myopia control.

PMID:
43036647
Bibliographic data and abstract were imported from PubMed on 16 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 11
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement