Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Cognitive load and mobility: Within-session repeatability and preliminary group discrimination of a dual-task 10-Meter Walk Test with Stroop in Parkinson's disease.

Created on 16 Nov 2026

Authors

Valerie Carter, John Heick, Tarang K Jain

Published in

Clinical parkinsonism & related disorders. Volume 15. Pages 100528. Epub Nov 05, 2026.

Abstract

Cognitive-motor interference during gait is commonly observed in individuals with Parkinson's disease (PD) and may contribute to mobility limitations and increased fall risk. Traditional single-task gait measures may underestimate mobility limitations in complex environments.
To examine whether integrating a visual Stroop task with the 10-Meter Walk Test (10MWT) differentiates walking performance between individuals with PD and healthy adults, and to evaluate the within-session repeatability of the Stroop-enhanced 10MWT.
Twenty participants with Parkinson's disease (PwP), 19 healthy older adults, and 19 healthy young adults were included in the complete-case walking analyses involving the 10MWT, Standing Stroop, and Stroop-enhanced 10MWT. Participants with PD additionally completed the TUG-cognitive. Completion times, Stroop errors, and gait dual-task costs were analyzed. Group comparisons were supplemented by sensitivity analyses, and within-session repeatability was evaluated using intraclass correlation coefficients from three trials. Results: Single-task 10MWT completion times did not differ significantly among groups (p = .211). During the Stroop-enhanced 10MWT, PwP demonstrated longer completion times than healthy older adults (13.24 ± 4.84 vs. 10.34 ± 2.49 s; unadjusted p = .025) and more Stroop errors (0.85 ± 0.72 vs. 0.37 ± 0.43 errors per trial; unadjusted p = .016). Although gait dual-task cost was numerically greater in PwP than in older adults (50.36 ± 34.26% vs. 34.61 ± 28.24%), the difference was not statistically significant (p = .125). The Stroop-enhanced 10MWT demonstrated excellent within-session repeatability (ICC[2,1] = 0.947).
The Stroop-enhanced 10MWT identified differences in dual-task walking performance between PwP and healthy older adults that were not observed during single-task walking. Its excellent within-session repeatability and preliminary ability to differentiate groups suggest potential utility for assessing cognitive-motor interference in PD. Further studies are needed to establish its validity, between-session reliability, and clinical applicability.

PMID:
43036633
Bibliographic data and abstract were imported from PubMed on 16 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 2
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement