Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Natural posture versus standardized position for the measurement of cervical sagittal alignment on X-rays: a prospective cohort study.

Created on 16 Nov 2026

Authors

Esther van Santbrink, Valérie Schuermans, Anouk Smeets, Rob de Bie, Henk van Santbrink, Toon Boselie

Published in

Brain & spine. Volume 6. Pages 107725. Epub Nov 02, 2026.

Abstract

Cervical sagittal alignment has been a key parameter for evaluating risk factors and outcomes in cervical spine pathology and surgery. This is generally measured on lateral X-rays. Reported normative alignment values vary widely between and within individuals. Body positioning throughout imaging procedures may contribute to this variability.
This study investigated the influence of body position on cervical sagittal alignment measured on lateral X-rays in asymptomatic individuals.
In this prospective cohort study, 20 asymptomatic individuals were included and received cervical and whole spine lateral X-rays in two standing positions at two time points, 6 to 8 weeks apart. The first position was a natural uninstructed posture (P1), and the second position was standardized, with head, arms, legs, and feet in an instructed position (P2). The primary outcome was the difference in C2-C7 Cobb angle.
Mean difference in C2-C7 Cobb angle between both positions was 6.9° ± 5.5° (p < 0.001). Gore angle, Harrison posterior tangent angle, C2-C7 sagittal vertical axis, McGregor angle, C0-C2 angle, and C0-C7 angle were also significantly different between the two positions. Mean intraobserver ICCs were excellent and mean interobserver ICCs were good.
Positioning during imaging of the cervical spine significantly influences cervical sagittal alignment and is of such a magnitude that it can induce a shift from lordosis to kyphosis. Consequently, cervical sagittal alignment values reported to date may be confounded. Defining patient positioning is essential to ensure reliable and comparable outcome measurements in both research and clinical settings.

PMID:
43036821
Bibliographic data and abstract were imported from PubMed on 16 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement