Prashant Kumar, Elisa Valentim Goulart, Hao Sun, John Kaiser Calautit, Karina Corada Pérez, Wenjie Song, Sandra Giulia Linnea Persiani, Kamaldeep Bhui, Douglas Booker, Brian Considine, Hossein Fatahian, Bruño Fraga, Bruno Furieri, Yuhan Huang, Peter J Irga, Laurence Jones, Priyanka Kulshreshtha, Ashok K Luhar, Giovanni Lo Lacono, Maria Clara Vieira Martins Starling, Aonghus McNabola, Rakesh Mishra, Lidia Morawska, Zaheer A Nasir, James O'Donnell, Hamid Omidvarborna, Christian Pfrang, Priyadarsini Rajagopalan, Neyval Costa Reis Junior, Robyn Schofield, Jane Meri Santos, Elson Silva Galvão, Divyanshu Sood, Taciana Toledo de Almeida Albuquerque, Jannis Wenk
Published in
Eco-Environment & Health. Volume 5. Issue 4. Pages 100289. Epub Oct 09, 2026.
Abstract
Indoor green infrastructures (iGI) can improve indoor environmental quality (IEQ), but inconsistent quantification methods undermine confidence in reported benefits and limit evidence-based design. This review synthesises monitoring and modelling methods to assess iGI impacts on IEQ, including outdoor-indoor interactions and climate change effects. Sixty studies were reviewed covering passive (potted plants, green walls, and indoor trees) and active (hydroponics, biofilters) systems. Both improve IEQ, with varying outcomes depending on configuration and environmental conditions. Passive systems, dominated by potted plants and green walls, demonstrate VOC reduction (typically 10%-30%) and help regulate temperature and humidity, while active systems achieve superior removal efficiencies for VOCs and particulate matter. The literature skews toward laboratory studies (59%) versus in-situ monitoring (33%). Many studies rely on short-duration chamber experiments (<1 m3; 6-48 h). Controlled settings report higher pollutant removal than real buildings, complicated by non-standardised iGI descriptors and ventilation data. Studies focus on a few plant taxa (Chlorophytum, Philodendron, Epipremnum, Spathiphyllum), measuring primarily temperature, humidity, and CO2. Modelling is context-specific, mainly targeting hygrothermal and CO2 processes in wall systems. Impacts depend on ventilation, lighting and greening intensity, with passive configurations reducing cooling demand by 22%-27% and low-light conditions weakening CO2 uptake [about 25 to 70 μmol/(m2∙s) PAR]. Outdoor-indoor interaction studies remain rare and poorly quantified. Few address future climate scenarios, creating uncertainty about benefits versus risks of elevated humidity, condensation/mould, and pollutant re-emission. Current practices inadequately attribute IEQ impacts to iGI interventions. Advancement requires standardised reporting protocols, integrated monitoring-modelling, explicit outdoor-indoor coupling, and climate-aware assessments with defined uncertainty boundaries.
PMID:
43036674
Bibliographic data and abstract were imported from PubMed on 16 Nov 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 9
- Comments 0