Electrical impedance spectroscopy and tomography for characterizing electrical changes associated with amoxicillin dispersion in ex vivo biological tissues.

Created on 16 Nov 2026

Authors

Manuel Vázquez-Nambo, José-Antonio Gutiérrez-Gnecchi, Enrique Reyes-Archundia, Wuqiang Yang, Daniel Lorias-Espinoza, Marcial Reyes-Cazares

Published in

Journal of electrical bioimpedance. Volume 17. Issue 1. Pages 183-197. Epub Nov 09, 2026.

Abstract

Studies of ionic liquid dispersion in biological samples are essential for improving dosages, minimizing side effects, and increasing treatment efficacy. Therefore, monitoring drug dispersion is crucial for understanding spatial and temporal drug transport.
The study evaluates electrochemical impedance spectroscopy (EIS) and electrical impedance tomography (EIT) to characterize electrical changes associated with amoxibron administration and its spatial propagation in ex vivo tissues, in a frequency range of 1 Hz to 10 kHz for EIS and 10, 50, and 100 kHz for EIT.
A gold electrode was used for EIS and a 16-electrode array for EIT. Three 5-mL doses of the amoxibron (C16H19N3O5S) drug were injected into each tissue sample at 2-min intervals. The electrical changes were analyzed using impedance spectra, equivalent electrical models, and resistivity distributions. To support the study, an additional test in beef tissue was conducted that included a measurement from 0 to 22 minutes.
At low frequencies, beef tissue showed the highest impedance of 20 kΩ, followed by pork and chicken with values of 11 kΩ and 10 kΩ, respectively. Drug administration impedance was reduced by approximately 50% in beef, 40-45% in chicken, and 10-15% in pork. The fitting accuracies of the state-space models were above 90% in all samples.
The resistivity maps showed diffusion resulting from impedance differences between tissue treated and untreated with the drug. Beef and chicken showed similar diffusion toward the periphery, whereas pork showed minimal changes over time toward the center. The temporal and spatial electrical changes were associated with amoxibron delivery, with differences in electrical response among tissues. The spatial resolution and localization performance of the EIT images were quantified using full width at half maximum (FWHM). The localization error was approximately 44 to 59% relative to the FWHM.

PMID:
43036750
Bibliographic data and abstract were imported from PubMed on 16 Nov 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 12
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement